{"api_version":"1","generated_at":"2026-08-19T11:44:40+00:00","cve":"CVE-2026-32657","urls":{"html":"https://cve.report/CVE-2026-32657","api":"https://cve.report/api/cve/CVE-2026-32657.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-32657","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-32657"},"summary":{"title":"CVE-2026-32657","description":"Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.377.00 and 46.382.00 and Dell PowerFlex Rack version 4.5.4 and prior versions, contain(s) an UNIX Symbolic Link (Symlink) Following vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.","state":"PUBLISHED","assigner":"dell","published_at":"2026-08-18 18:17:28","updated_at":"2026-08-19 04:16:58"},"problem_types":["CWE-61","CWE-61 CWE-61: UNIX Symbolic Link (Symlink) Following"],"metrics":[{"version":"3.1","source":"security_alert@emc.com","type":"Secondary","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000497857/dsa-2026-220-security-update-for-dell-product-vulnerability","name":"https://www.dell.com/support/kbdoc/en-us/000497857/dsa-2026-220-security-update-for-dell-product-vulnerability","refsource":"security_alert@emc.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-32657","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-32657","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Dell","product":"AppSync","version":"affected 4.6.0.4 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"Metro Node","version":"affected 4.6.0.4 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"UCC Edge","version":"affected 3.0.2 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"VxRail","version":"affected 8.0.330 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerMax","version":"affected 10.3.1.0 Patch 11248 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"Unity","version":"affected 5.5.2 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerFlex Manager","version":"affected 4.5.5 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerFlex Intelligent Catalog","version":"affected 48.383.00 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerFlex Intelligent Catalog","version":"affected 48.378.00 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerFlex Rack","version":"affected 4.5.5 or later semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-32657","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-08-18T00:00:00+00:00","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-19T03:56:07.666Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"AppSync","vendor":"Dell","versions":[{"lessThan":"4.6.0.4 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Metro Node","vendor":"Dell","versions":[{"lessThan":"4.6.0.4 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"UCC Edge","vendor":"Dell","versions":[{"lessThan":"3.0.2 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VxRail","vendor":"Dell","versions":[{"lessThan":"8.0.330 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"PowerMax","vendor":"Dell","versions":[{"lessThan":"10.3.1.0 Patch 11248 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Unity","vendor":"Dell","versions":[{"lessThan":"5.5.2 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"PowerFlex Manager","vendor":"Dell","versions":[{"lessThan":"4.5.5 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"PowerFlex Intelligent Catalog","vendor":"Dell","versions":[{"lessThan":"48.383.00 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"PowerFlex Intelligent Catalog","vendor":"Dell","versions":[{"lessThan":"48.378.00 or later","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"PowerFlex Rack","vendor":"Dell","versions":[{"lessThan":"4.5.5 or later","status":"affected","version":"0","versionType":"semver"}]}],"datePublic":"2026-08-10T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.377.00 and 46.382.00 and Dell PowerFlex Rack version 4.5.4 and prior versions, contain(s) an UNIX Symbolic Link (Symlink) Following vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."}],"value":"Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.377.00 and 46.382.00 and Dell PowerFlex Rack version 4.5.4 and prior versions, contain(s) an UNIX Symbolic Link (Symlink) Following vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-61","description":"CWE-61: UNIX Symbolic Link (Symlink) Following","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-18T17:50:21.914Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000497857/dsa-2026-220-security-update-for-dell-product-vulnerability"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.4"}}},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2026-32657","datePublished":"2026-08-18T17:50:21.914Z","dateReserved":"2026-03-12T17:04:27.868Z","dateUpdated":"2026-08-19T03:56:07.666Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-18 18:17:28","lastModifiedDate":"2026-08-19 04:16:58","problem_types":["CWE-61","CWE-61 CWE-61: UNIX Symbolic Link (Symlink) Following"],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-18T00:00:00+00:00","id":"CVE-2026-32657","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"32657","Ordinal":"1","Title":"CVE-2026-32657","CVE":"CVE-2026-32657","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"32657","Ordinal":"1","NoteData":"Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.377.00 and 46.382.00 and Dell PowerFlex Rack version 4.5.4 and prior versions, contain(s) an UNIX Symbolic Link (Symlink) Following vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.","Type":"Description","Title":"CVE-2026-32657"}]}}}