{"api_version":"1","generated_at":"2026-10-09T16:52:11+00:00","cve":"CVE-2026-33367","urls":{"html":"https://cve.report/CVE-2026-33367","api":"https://cve.report/api/cve/CVE-2026-33367.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-33367","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-33367"},"summary":{"title":"Red Lion Controls N-Tron 700 Series Missing Authentication for Critical Function","description":"SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication.","state":"PUBLISHED","assigner":"icscert","published_at":"2026-10-09 15:17:14","updated_at":"2026-10-09 15:17:14"},"problem_types":["CWE-306","CWE-306 CWE-306"],"metrics":[{"version":"4.0","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"9.3","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.3","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"8.1","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.1","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}}],"references":[{"url":"https://www.hms-networks.com/cybersecurity","name":"https://www.hms-networks.com/cybersecurity","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.hms-networks.com/","name":"https://www.hms-networks.com/","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json","name":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-33367","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-33367","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Red Lion Controls","product":"700 Series","version":"affected Firmware Versions 3.11.0 custom","platforms":[]},{"source":"CNA","vendor":"Red Lion Controls","product":"700 Series","version":"affected Bootloader Versions 2.0.6.1 custom","platforms":[]},{"source":"CNA","vendor":"Red Lion Controls","product":"700 Series","version":"unaffected 3.11.1","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \n\n\n  *  Upgrade to firmware version 3.11.1 or greater\n  *  Configure or disable the SNMP communities\n  *  Disable access to the web GUI\n\n\n\n\n\nThe upgrade procedure document can be viewed  here https://www.hms-networks.com/ .\n\n\n\n\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed  here https://www.hms-networks.com/cybersecurity .","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"700 Series","vendor":"Red Lion Controls","versions":[{"lessThan":"Firmware Versions 3.11.0","status":"affected","version":"0","versionType":"custom"},{"lessThan":"Bootloader Versions 2.0.6.1","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"3.11.1"}]}],"credits":[{"lang":"en","type":"finder","value":"Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication."}],"value":"SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-09T14:38:37.795Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"url":"https://www.hms-networks.com/"},{"url":"https://www.hms-networks.com/cybersecurity"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Red Lion controls recommends the following upgrades for the N-Tron 700 Series: <br></p><ul><li>Upgrade to firmware version 3.11.1 or greater</li><li>Configure or disable the SNMP communities</li><li>Disable access to the web GUI</li></ul>\n<p>The upgrade procedure document can be viewed <a href=\"https://www.hms-networks.com/\">here</a>.</p>\n<p>The advisory issued by HMS Networks regarding these vulnerabilities can be viewed <a href=\"https://www.hms-networks.com/cybersecurity\">here</a>.</p>"}],"value":"Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \n\n\n  *  Upgrade to firmware version 3.11.1 or greater\n  *  Configure or disable the SNMP communities\n  *  Disable access to the web GUI\n\n\n\n\n\nThe upgrade procedure document can be viewed  here https://www.hms-networks.com/ .\n\n\n\n\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed  here https://www.hms-networks.com/cybersecurity ."}],"source":{"advisory":"ICSA-26-281-01","discovery":"EXTERNAL"},"title":"Red Lion Controls N-Tron 700 Series Missing Authentication for Critical Function","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2026-33367","datePublished":"2026-10-09T14:38:37.795Z","dateReserved":"2026-04-08T19:28:49.496Z","dateUpdated":"2026-10-09T14:38:37.795Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-09 15:17:14","lastModifiedDate":"2026-10-09 15:17:14","problem_types":["CWE-306","CWE-306 CWE-306"],"metrics":{"cvssMetricV40":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":5.2}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"33367","Ordinal":"1","Title":"Red Lion Controls N-Tron 700 Series Missing Authentication for C","CVE":"CVE-2026-33367","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"33367","Ordinal":"1","NoteData":"SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication.","Type":"Description","Title":"Red Lion Controls N-Tron 700 Series Missing Authentication for C"}]}}}