{"api_version":"1","generated_at":"2026-11-23T04:41:18+00:00","cve":"CVE-2026-33389","urls":{"html":"https://cve.report/CVE-2026-33389","api":"https://cve.report/api/cve/CVE-2026-33389.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-33389","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-33389"},"summary":{"title":"Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0","description":"An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations.","state":"PUBLISHED","assigner":"Nozomi","published_at":"2026-09-08 14:17:22","updated_at":"2026-10-15 02:19:21"},"problem_types":["CWE-671","CWE-671 CWE-671 Lack of Administrator Control over Security"],"metrics":[{"version":"4.0","source":"prodsec@nozominetworks.com","type":"Secondary","score":"5.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"5.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"prodsec@nozominetworks.com","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","data":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","version":"3.1"}}],"references":[{"url":"https://security.nozominetworks.com/NN-2026:20-01","name":"https://security.nozominetworks.com/NN-2026:20-01","refsource":"prodsec@nozominetworks.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-911336.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-911336.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-33389","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-33389","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Nozomi Networks","product":"Guardian","version":"affected 26.3.0 semver","platforms":[]},{"source":"CNA","vendor":"Nozomi Networks","product":"CMC","version":"affected 26.3.0 semver","platforms":[]},{"source":"CNA","vendor":"Nozomi Networks","product":"Arc","version":"affected 2.7.0 semver","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM APE1808","version":"affected * custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"This issue was found by Stefano Balzarotti of Nozomi Networks and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-33389","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-09-08T14:19:40.637992Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-08T14:19:48.707Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM APE1808","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-10-15T01:18:22.831Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-911336.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Guardian","vendor":"Nozomi Networks","versions":[{"lessThan":"26.3.0","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CMC","vendor":"Nozomi Networks","versions":[{"lessThan":"26.3.0","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Arc","vendor":"Nozomi Networks","versions":[{"lessThan":"2.7.0","status":"affected","version":"0","versionType":"semver"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*","versionEndExcluding":"26.3.0","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*","versionEndExcluding":"26.3.0","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:nozomi_networks:arc:*:*:*:*:*:*:*:*","versionEndExcluding":"2.7.0","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"This issue was found by Stefano Balzarotti of Nozomi Networks and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."}],"datePublic":"2026-09-08T07:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations."}],"value":"An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations."}],"impacts":[{"capecId":"CAPEC-94","descriptions":[{"lang":"en","value":"CAPEC-94 Adversary in the Middle (AiTM)"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-671","description":"CWE-671 Lack of Administrator Control over Security","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-08T13:55:16.115Z","orgId":"bec8025f-a851-46e5-b3a3-058e6b0aa23c","shortName":"Nozomi"},"references":[{"url":"https://security.nozominetworks.com/NN-2026:20-01"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later.<br>"}],"value":"Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later."}],"source":{"discovery":"INTERNAL"},"title":"Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"bec8025f-a851-46e5-b3a3-058e6b0aa23c","assignerShortName":"Nozomi","cveId":"CVE-2026-33389","datePublished":"2026-09-08T13:55:16.115Z","dateReserved":"2026-03-19T11:28:43.172Z","dateUpdated":"2026-10-15T01:18:22.831Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-08 14:17:22","lastModifiedDate":"2026-10-15 02:19:21","problem_types":["CWE-671","CWE-671 CWE-671 Lack of Administrator Control over Security"],"metrics":{"cvssMetricV40":[{"source":"prodsec@nozominetworks.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"prodsec@nozominetworks.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":1.6,"impactScore":5.3}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-08T14:19:40.637992Z","id":"CVE-2026-33389","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"33389","Ordinal":"1","Title":"Disabled and non-configurable certificate/host key validation in","CVE":"CVE-2026-33389","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"33389","Ordinal":"1","NoteData":"An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations.","Type":"Description","Title":"Disabled and non-configurable certificate/host key validation in"}]}}}