{"api_version":"1","generated_at":"2026-05-13T05:23:08+00:00","cve":"CVE-2026-3561","urls":{"html":"https://cve.report/CVE-2026-3561","api":"https://cve.report/api/cve/CVE-2026-3561.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-3561","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-3561"},"summary":{"title":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability","description":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-03-16 14:19:52","updated_at":"2026-04-27 14:30:01"},"problem_types":["CWE-122","CWE-122 CWE-122: Heap-based Buffer Overflow"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-159/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-159/","refsource":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-3561","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-3561","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Philips","product":"Hue Bridge","version":"affected 1.73.1973146020","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2026","cve_id":"3561","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"philips","cpe5":"hue_bridge_v2","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2026","cve_id":"3561","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"philips","cpe5":"hue_bridge_v2_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"3561","cve":"CVE-2026-3561","epss":"0.001510000","percentile":"0.353920000","score_date":"2026-04-27","updated_at":"2026-04-28 00:06:44"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-3561","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-03-16T20:20:49.680668Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-03-16T20:21:04.470Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Hue Bridge","vendor":"Philips","versions":[{"status":"affected","version":"1.73.1973146020"}]}],"dateAssigned":"2026-03-04T19:42:53.455Z","datePublic":"2026-03-06T21:19:38.258Z","descriptions":[{"lang":"en","value":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."}],"metrics":[{"cvssV3_0":{"baseScore":8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-122","description":"CWE-122: Heap-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-03-13T20:37:05.625Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-159","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-159/"}],"source":{"lang":"en","value":"Thalium team from Thales Group (@thalium_team)"},"title":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-3561","datePublished":"2026-03-13T20:37:05.625Z","dateReserved":"2026-03-04T19:42:53.419Z","dateUpdated":"2026-03-16T20:21:04.470Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-03-16 14:19:52","lastModifiedDate":"2026-04-27 14:30:01","problem_types":["CWE-122","CWE-122 CWE-122: Heap-based Buffer Overflow"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"3561","Ordinal":"1","Title":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Over","CVE":"CVE-2026-3561","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"3561","Ordinal":"1","NoteData":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479.","Type":"Description","Title":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Over"}]}}}