{"api_version":"1","generated_at":"2026-07-05T20:20:04+00:00","cve":"CVE-2026-36174","urls":{"html":"https://cve.report/CVE-2026-36174","api":"https://cve.report/api/cve/CVE-2026-36174.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-36174","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-36174"},"summary":{"title":"CVE-2026-36174","description":"GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.","state":"PUBLISHED","assigner":"mitre","published_at":"2026-06-04 15:16:51","updated_at":"2026-07-05 17:17:30"},"problem_types":["CWE-256","n/a","CWE-256 CWE-256 Plaintext Storage of a Password"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"4.6","severity":"MEDIUM","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"4.6","severity":"MEDIUM","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":4.6,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md","name":"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://gncc.com","name":"http://gncc.com","refsource":"MITRE","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://gp5.com","name":"http://gp5.com","refsource":"MITRE","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-36174","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-36174","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"36174","cve":"CVE-2026-36174","epss":"0.000190000","percentile":"0.053500000","score_date":"2026-06-14","updated_at":"2026-06-15 00:14:09"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}},{"other":{"content":{"id":"CVE-2026-36174","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-06-08T13:59:07.714870Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-256","description":"CWE-256 Plaintext Storage of a Password","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-08T14:00:45.789Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["exploit"],"url":"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2026-07-05T16:16:48.001Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2026-36174","datePublished":"2026-06-04T00:00:00.000Z","dateReserved":"2026-04-06T00:00:00.000Z","dateUpdated":"2026-07-05T16:16:48.001Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-06-04 15:16:51","lastModifiedDate":"2026-07-05 17:17:30","problem_types":["CWE-256","n/a","CWE-256 CWE-256 Plaintext Storage of a Password"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":4.6,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-06-08T13:59:07.714870Z","id":"CVE-2026-36174","options":[{"exploitation":"poc"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"36174","Ordinal":"1","Title":"CVE-2026-36174","CVE":"CVE-2026-36174","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"36174","Ordinal":"1","NoteData":"GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.","Type":"Description","Title":"CVE-2026-36174"}]}}}