{"api_version":"1","generated_at":"2026-07-21T15:09:19+00:00","cve":"CVE-2026-40851","urls":{"html":"https://cve.report/CVE-2026-40851","api":"https://cve.report/api/cve/CVE-2026-40851.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-40851","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-40851"},"summary":{"title":"Command injection via USB","description":"A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.","state":"PUBLISHED","assigner":"CERTVDE","published_at":"2026-05-27 09:16:31","updated_at":"2026-05-27 14:53:22"},"problem_types":["CWE-1287","CWE-1287 CWE-1287 Improper Validation of Specified Type of Input"],"metrics":[{"version":"3.1","source":"info@cert.vde.com","type":"Primary","score":"8.4","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.4","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.certvde.com/en/advisories/VDE-2026-054/","name":"https://www.certvde.com/en/advisories/VDE-2026-054/","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-40851","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-40851","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"MB connect line","product":"mbNET/mbNET.rokey","version":"affected 0.0.0 8.4.4 semver","platforms":[]},{"source":"CNA","vendor":"MB connect line","product":"mbNET.mini","version":"affected 0.0.0 3.0.2 semver","platforms":[]},{"source":"CNA","vendor":"MB connect line","product":"mbNET/mbNET.rokey","version":"affected 8.4.4","platforms":[]},{"source":"CNA","vendor":"MB connect line","product":"mbNET.mini","version":"affected 3.0.2","platforms":[]},{"source":"CNA","vendor":"Helmholz","product":"REX200/250","version":"affected 0.0.0 8.4.4 semver","platforms":[]},{"source":"CNA","vendor":"Helmholz","product":"REX100","version":"affected 0.0.0 3.0.2 semver","platforms":[]},{"source":"CNA","vendor":"Helmholz","product":"REX200/250","version":"affected 8.4.4","platforms":[]},{"source":"CNA","vendor":"Helmholz","product":"REX100","version":"affected 3.0.2","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Moritz Abrell from SySS GmbH","lang":"en"},{"source":"CNA","value":"Christian Zäske from SySS GmbH","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"40851","cve":"CVE-2026-40851","epss":"0.000220000","percentile":"0.066060000","score_date":"2026-05-31","updated_at":"2026-06-01 00:08:19"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-40851","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-27T11:44:44.253548Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-27T11:54:33.819Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"mbNET/mbNET.rokey","vendor":"MB connect line","versions":[{"lessThanOrEqual":"8.4.4","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"mbNET.mini","vendor":"MB connect line","versions":[{"lessThanOrEqual":"3.0.2","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"mbNET/mbNET.rokey","vendor":"MB connect line","versions":[{"status":"affected","version":"8.4.4"}]},{"defaultStatus":"unaffected","product":"mbNET.mini","vendor":"MB connect line","versions":[{"status":"affected","version":"3.0.2"}]},{"defaultStatus":"unaffected","product":"REX200/250","vendor":"Helmholz","versions":[{"lessThanOrEqual":"8.4.4","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"REX100","vendor":"Helmholz","versions":[{"lessThanOrEqual":"3.0.2","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"REX200/250","vendor":"Helmholz","versions":[{"status":"affected","version":"8.4.4"}]},{"defaultStatus":"unaffected","product":"REX100","vendor":"Helmholz","versions":[{"status":"affected","version":"3.0.2"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*","versionEndIncluding":"8.4.4","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*","versionEndIncluding":"3.0.2","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*","versionStartIncluding":"8.4.4","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*","versionStartIncluding":"3.0.2","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*","versionEndIncluding":"8.4.4","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*","versionEndIncluding":"3.0.2","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*","versionStartIncluding":"8.4.4","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*","versionStartIncluding":"3.0.2","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Moritz Abrell from SySS GmbH"},{"lang":"en","type":"finder","value":"Christian Zäske from SySS GmbH"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.</p>"}],"value":"A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1287","description":"CWE-1287 Improper Validation of Specified Type of Input","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-27T08:06:21.815Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"url":"https://www.certvde.com/en/advisories/VDE-2026-054/"}],"source":{"advisory":"VDE-2026-054","defect":["CERT@VDE#642070"],"discovery":"UNKNOWN"},"title":"Command injection via USB","x_generator":{"engine":"Vulnogram 0.4.0"}}},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2026-40851","datePublished":"2026-05-27T08:06:21.815Z","dateReserved":"2026-04-15T09:33:02.614Z","dateUpdated":"2026-05-27T11:54:33.819Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-27 09:16:31","lastModifiedDate":"2026-05-27 14:53:22","problem_types":["CWE-1287","CWE-1287 CWE-1287 Improper Validation of Specified Type of Input"],"metrics":{"cvssMetricV31":[{"source":"info@cert.vde.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.5,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"40851","Ordinal":"1","Title":"Command injection via USB","CVE":"CVE-2026-40851","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"40851","Ordinal":"1","NoteData":"A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.","Type":"Description","Title":"Command injection via USB"}]}}}