{"api_version":"1","generated_at":"2026-09-13T11:42:36+00:00","cve":"CVE-2026-42807","urls":{"html":"https://cve.report/CVE-2026-42807","api":"https://cve.report/api/cve/CVE-2026-42807.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-42807","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-42807"},"summary":{"title":"CVE-2026-42807","description":"A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.","state":"PUBLISHED","assigner":"bosch","published_at":"2026-09-10 09:17:02","updated_at":"2026-09-10 16:17:12"},"problem_types":["CWE-122","CWE-122 CWE-122 Heap-based Buffer Overflow"],"metrics":[{"version":"3.1","source":"psirt@bosch.com","type":"Secondary","score":"8","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"8","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html","refsource":"psirt@bosch.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-42807","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-42807","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Bosch Sensortec","product":"COINES_SDK","version":"affected 2.10 2.12.2 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"42807","cve":"CVE-2026-42807","epss":"0.002040000","percentile":"0.104950000","score_date":"2026-09-12","updated_at":"2026-09-13 00:08:19"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-42807","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-10T14:59:49.196198Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-10T15:00:04.892Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"COINES_SDK","vendor":"Bosch Sensortec","versions":[{"lessThanOrEqual":"2.12.2","status":"affected","version":"2.10","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-122","description":"CWE-122 Heap-based Buffer Overflow","lang":"en-US"}]}],"providerMetadata":{"dateUpdated":"2026-09-10T09:05:10.550Z","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","shortName":"bosch"},"references":[{"name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html","tags":["vendor-advisory"],"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"}]}},"cveMetadata":{"assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","assignerShortName":"bosch","cveId":"CVE-2026-42807","datePublished":"2026-09-10T09:05:10.550Z","dateReserved":"2026-04-30T08:03:11.875Z","dateUpdated":"2026-09-10T15:00:04.892Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-10 09:17:02","lastModifiedDate":"2026-09-10 16:17:12","problem_types":["CWE-122","CWE-122 CWE-122 Heap-based Buffer Overflow"],"metrics":{"cvssMetricV31":[{"source":"psirt@bosch.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-10T14:59:49.196198Z","id":"CVE-2026-42807","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"42807","Ordinal":"1","Title":"CVE-2026-42807","CVE":"CVE-2026-42807","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"42807","Ordinal":"1","NoteData":"A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.","Type":"Description","Title":"CVE-2026-42807"}]}}}