{"api_version":"1","generated_at":"2026-08-28T03:53:06+00:00","cve":"CVE-2026-44629","urls":{"html":"https://cve.report/CVE-2026-44629","api":"https://cve.report/api/cve/CVE-2026-44629.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-44629","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-44629"},"summary":{"title":"CVE-2026-44629","description":"Improper access control to the Synergis Softwire installation folder. This vulnerability affects Streamvault all-in-one appliances (SV-100E and SV-300E series) and Synergis Softwire installed on Windows servers.","state":"PUBLISHED","assigner":"Genetec","published_at":"2026-08-28 00:17:28","updated_at":"2026-08-28 00:17:28"},"problem_types":["CWE-922","CWE-922 CWE-922: Insecure Storage of Sensitive Information"],"metrics":[{"version":"3.1","source":"security@genetec.com","type":"Secondary","score":"7.9","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","baseScore":7.9,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.9","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","data":{"baseScore":7.9,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","version":"3.1"}}],"references":[{"url":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.2/Resolved-vulnerabilities-in-Synergis-Softwire-12.2.0","name":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.2/Resolved-vulnerabilities-in-Synergis-Softwire-12.2.0","refsource":"security@genetec.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.0/Resolved-vulnerabilities-in-Synergis-Softwire-12.0.2","name":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.0/Resolved-vulnerabilities-in-Synergis-Softwire-12.0.2","refsource":"security@genetec.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-44629","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-44629","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Genetec Inc.","product":"Synergis Softwire","version":"unaffected >=12.0.2 semver","platforms":["Streamvault all-in-one appliances (SV-100E and SV-300E series)","Windows (Softwire installed on a server)"]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["Streamvault all-in-one appliances (SV-100E and SV-300E series)","Windows (Softwire installed on a server)"],"product":"Synergis Softwire","vendor":"Genetec Inc.","versions":[{"status":"unaffected","version":">=12.0.2","versionType":"semver"}]}],"descriptions":[{"lang":"en","value":"Improper access control to the Synergis Softwire installation folder. This vulnerability affects Streamvault all-in-one appliances (SV-100E and SV-300E series) and Synergis Softwire installed on Windows servers."}],"impacts":[{"capecId":"CAPEC-639","descriptions":[{"lang":"en","value":"CAPEC-639: Probe System Files"}]}],"metrics":[{"cvssV3_1":{"baseScore":7.9,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-922","description":"CWE-922: Insecure Storage of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-27T22:08:52.736Z","orgId":"f2b06212-cb4b-41a4-9501-fa2e367495b8","shortName":"Genetec"},"references":[{"url":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.0/Resolved-vulnerabilities-in-Synergis-Softwire-12.0.2"},{"url":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SynergisTM-Softwire-12.2/Resolved-vulnerabilities-in-Synergis-Softwire-12.2.0"}]}},"cveMetadata":{"assignerOrgId":"f2b06212-cb4b-41a4-9501-fa2e367495b8","assignerShortName":"Genetec","cveId":"CVE-2026-44629","datePublished":"2026-08-27T22:08:52.736Z","dateReserved":"2026-05-11T18:46:18.567Z","dateUpdated":"2026-08-27T22:08:52.736Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-28 00:17:28","lastModifiedDate":"2026-08-28 00:17:28","problem_types":["CWE-922","CWE-922 CWE-922: Insecure Storage of Sensitive Information"],"metrics":{"cvssMetricV31":[{"source":"security@genetec.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L","baseScore":7.9,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2,"impactScore":5.3}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"44629","Ordinal":"1","Title":"CVE-2026-44629","CVE":"CVE-2026-44629","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"44629","Ordinal":"1","NoteData":"Improper access control to the Synergis Softwire installation folder. This vulnerability affects Streamvault all-in-one appliances (SV-100E and SV-300E series) and Synergis Softwire installed on Windows servers.","Type":"Description","Title":"CVE-2026-44629"}]}}}