{"api_version":"1","generated_at":"2026-07-03T18:06:41+00:00","cve":"CVE-2026-46464","urls":{"html":"https://cve.report/CVE-2026-46464","api":"https://cve.report/api/cve/CVE-2026-46464.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-46464","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-46464"},"summary":{"title":"CVE-2026-46464","description":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure.","state":"PUBLISHED","assigner":"dell","published_at":"2026-07-03 14:16:30","updated_at":"2026-07-03 14:16:30"},"problem_types":["CWE-59","CWE-59 CWE-59: Improper Link Resolution Before File Access ('Link Following')"],"metrics":[{"version":"3.1","source":"security_alert@emc.com","type":"Secondary","score":"4.9","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"4.9","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","name":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","refsource":"security_alert@emc.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-46464","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-46464","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.8.0.0 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.6.1.20 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.3.1.40 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 7.13.1.80 or later semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerProtect Data Domain","vendor":"Dell","versions":[{"lessThan":"8.8.0.0 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.6.1.20 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.3.1.40 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"7.13.1.80 or later","status":"affected","version":"0","versionType":"semver"}]}],"datePublic":"2026-07-02T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."}],"value":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-59","description":"CWE-59: Improper Link Resolution Before File Access ('Link Following')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-07-03T13:32:35.091Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2026-46464","datePublished":"2026-07-03T13:32:35.091Z","dateReserved":"2026-05-14T17:05:39.859Z","dateUpdated":"2026-07-03T13:32:35.091Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-07-03 14:16:30","lastModifiedDate":"2026-07-03 14:16:30","problem_types":["CWE-59","CWE-59 CWE-59: Improper Link Resolution Before File Access ('Link Following')"],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.2,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"46464","Ordinal":"1","Title":"CVE-2026-46464","CVE":"CVE-2026-46464","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"46464","Ordinal":"1","NoteData":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure.","Type":"Description","Title":"CVE-2026-46464"}]}}}