{"api_version":"1","generated_at":"2026-07-03T18:06:41+00:00","cve":"CVE-2026-46468","urls":{"html":"https://cve.report/CVE-2026-46468","api":"https://cve.report/api/cve/CVE-2026-46468.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-46468","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-46468"},"summary":{"title":"CVE-2026-46468","description":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.","state":"PUBLISHED","assigner":"dell","published_at":"2026-07-03 13:17:23","updated_at":"2026-07-03 13:17:23"},"problem_types":["CWE-59","CWE-59 CWE-59: Improper Link Resolution Before File Access ('Link Following')"],"metrics":[{"version":"3.1","source":"security_alert@emc.com","type":"Secondary","score":"4.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"4.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":4.4,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","name":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","refsource":"security_alert@emc.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-46468","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-46468","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.8.0.0 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.6.1.20 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.3.1.40 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 7.13.1.80 or later semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerProtect Data Domain","vendor":"Dell","versions":[{"lessThan":"8.8.0.0 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.6.1.20 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.3.1.40 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"7.13.1.80 or later","status":"affected","version":"0","versionType":"semver"}]}],"datePublic":"2026-07-02T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."}],"value":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":4.4,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-59","description":"CWE-59: Improper Link Resolution Before File Access ('Link Following')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-07-03T12:58:46.278Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2026-46468","datePublished":"2026-07-03T12:58:46.278Z","dateReserved":"2026-05-14T17:05:39.859Z","dateUpdated":"2026-07-03T12:58:46.278Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-07-03 13:17:23","lastModifiedDate":"2026-07-03 13:17:23","problem_types":["CWE-59","CWE-59 CWE-59: Improper Link Resolution Before File Access ('Link Following')"],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"46468","Ordinal":"1","Title":"CVE-2026-46468","CVE":"CVE-2026-46468","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"46468","Ordinal":"1","NoteData":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.","Type":"Description","Title":"CVE-2026-46468"}]}}}