{"api_version":"1","generated_at":"2026-07-23T12:50:02+00:00","cve":"CVE-2026-4827","urls":{"html":"https://cve.report/CVE-2026-4827","api":"https://cve.report/api/cve/CVE-2026-4827.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-4827","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-4827"},"summary":{"title":"Insufficient Entropy vulnerability on Multiple Products","description":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.","state":"PUBLISHED","assigner":"schneider","published_at":"2026-05-12 13:17:35","updated_at":"2026-05-14 18:16:50"},"problem_types":["CWE-331","CWE-331 CWE-331 Insufficient entropy"],"metrics":[{"version":"4.0","source":"cybersecurity@se.com","type":"Secondary","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf","refsource":"cybersecurity@se.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-4827","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-4827","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM C264","version":"affected Versions D6.x","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM C264","version":"affected Versions D7.33 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy C5","version":"affected Version 1.1.17 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P139 version prior to P139.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P437 version prior to P437.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P439 version prior to P439.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P532 version prior to P532.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P539 version prior to P539.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P631 version prior to P631.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P632 version prior to P632.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P633 version prior to P633.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P634 version prior to P634.678.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P633 version P633.680.700 only","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P634 version P634.680.700 only","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P138 version prior to P138.677.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P436 version prior to P436.677.701","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P438 version prior to P438.677.701","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected P638 version prior to P638.677.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P30","version":"affected C434 version prior to C434.679.700","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P40","version":"affected Series model numbers with Protocol Option bit as G, H or L and all firmware versions","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","version":"affected Version 6.4.616.200.100 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","version":"affected Version 3.0.3 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","version":"affected Version 2022 CU6 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","version":"affected Version 2024 CU2 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"iPMFLS","version":"affected Version 64.2025.0.13 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"PowerLogic™ P5 Protection Relay","version":"affected V02.502.103 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"PowerLogic™ P7 Protection and Control Platform","version":"affected V02.002.002 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"PowerLogic™ T300","version":"affected Version 2.9.4 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"PowerLogic™ T500","version":"affected Version 11.08.02 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Saitel DP","version":"affected Version 11.06.36 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EasyLogic T150 (formerly Saitel DR)","version":"affected Version 11.06.30 and prior","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"4827","cve":"CVE-2026-4827","epss":"0.000660000","percentile":"0.203910000","score_date":"2026-05-25","updated_at":"2026-05-26 00:10:59"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-4827","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-12T12:39:02.210471Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-12T12:39:31.579Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Easergy MiCOM C264","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions D6.x"},{"status":"affected","version":"Versions D7.33 and prior"}]},{"defaultStatus":"unaffected","product":"Easergy C5","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 1.1.17 and prior"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P30","vendor":"Schneider Electric","versions":[{"status":"affected","version":"P139 version prior to P139.678.700"},{"status":"affected","version":"P437 version prior to P437.678.700"},{"status":"affected","version":"P439 version prior to P439.678.700"},{"status":"affected","version":"P532 version prior to P532.678.700"},{"status":"affected","version":"P539 version prior to P539.678.700"},{"status":"affected","version":"P631 version prior to P631.678.700"},{"status":"affected","version":"P632 version prior to P632.678.700"},{"status":"affected","version":"P633 version prior to P633.678.700"},{"status":"affected","version":"P634 version prior to P634.678.700"},{"status":"affected","version":"P633 version P633.680.700 only"},{"status":"affected","version":"P634 version P634.680.700 only"},{"status":"affected","version":"P138 version prior to P138.677.700"},{"status":"affected","version":"P436 version prior to P436.677.701"},{"status":"affected","version":"P438 version prior to P438.677.701"},{"status":"affected","version":"P638 version prior to P638.677.700"},{"status":"affected","version":"C434 version prior to C434.679.700"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P40","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 6.4.616.200.100 and prior"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 3.0.3 and prior"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Operation","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2022 CU6 and prior"},{"status":"affected","version":"Version 2024 CU2 and prior"}]},{"defaultStatus":"unaffected","product":"iPMFLS","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 64.2025.0.13 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ P5 Protection Relay","vendor":"Schneider Electric","versions":[{"status":"affected","version":"V02.502.103 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ P7 Protection and Control Platform","vendor":"Schneider Electric","versions":[{"status":"affected","version":"V02.002.002 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ T300","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2.9.4 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ T500","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.08.02 and prior"}]},{"defaultStatus":"unaffected","product":"Saitel DP","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.06.36 and prior"}]},{"defaultStatus":"unaffected","product":"EasyLogic T150 (formerly Saitel DR)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.06.30 and prior"}]}],"datePublic":"2026-05-12T16:49:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections."}],"value":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-331","description":"CWE-331 Insufficient entropy","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-14T17:38:38.647Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf"}],"source":{"discovery":"UNKNOWN"},"title":"Insufficient Entropy vulnerability on Multiple Products","x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2026-4827","datePublished":"2026-05-12T12:24:22.928Z","dateReserved":"2026-03-25T14:07:29.111Z","dateUpdated":"2026-05-14T17:38:38.647Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-12 13:17:35","lastModifiedDate":"2026-05-14 18:16:50","problem_types":["CWE-331","CWE-331 CWE-331 Insufficient entropy"],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"4827","Ordinal":"1","Title":"Insufficient Entropy vulnerability on Multiple Products","CVE":"CVE-2026-4827","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"4827","Ordinal":"1","NoteData":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.","Type":"Description","Title":"Insufficient Entropy vulnerability on Multiple Products"}]}}}