{"api_version":"1","generated_at":"2026-04-22T17:46:48+00:00","cve":"CVE-2026-4832","urls":{"html":"https://cve.report/CVE-2026-4832","api":"https://cve.report/api/cve/CVE-2026-4832.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-4832","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-4832"},"summary":{"title":"CVE-2026-4832","description":"CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.","state":"PUBLISHED","assigner":"schneider","published_at":"2026-04-14 16:16:48","updated_at":"2026-04-17 15:11:35"},"problem_types":["CWE-798","CWE-798 CWE-798 Use of Hard-Coded Credentials"],"metrics":[{"version":"4.0","source":"cybersecurity@se.com","type":"Secondary","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-03.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-03.pdf","refsource":"cybersecurity@se.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-4832","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-4832","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P14x","version":"affected All versions prior to B4A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P24x","version":"affected All versions prior to D3A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P341","version":"affected All versions prior to E3F","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P342, P343, P344, P345","version":"affected All versions prior to B3F","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P442, P444","version":"affected All versions prior to E3A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P443, P445, P446, P543, P544, P545, P546","version":"affected All versions prior to H6A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P642, P645","version":"affected All versions prior to B4A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P643","version":"affected All versions prior to B3F","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P741, P742, P743","version":"affected All versions prior to B2A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P746","version":"affected All versions prior to B4E or C4E","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P841","version":"affected All versions prior to G6A","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"Easergy MiCOM P849","version":"affected All versions prior to B4A","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"4832","cve":"CVE-2026-4832","epss":"0.000780000","percentile":"0.232630000","score_date":"2026-04-21","updated_at":"2026-04-22 00:07:41"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-4832","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-14T18:15:51.123382Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-04-14T18:16:06.726Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Easergy MiCOM P14x","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P24x","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to D3A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P341","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to E3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P342, P343, P344, P345","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P442, P444","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to E3A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P443, P445, P446, P543, P544, P545, P546","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to H6A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P642, P645","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P643","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P741, P742, P743","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B2A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P746","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4E or C4E"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P841","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to G6A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P849","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port."}],"value":"CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-798","description":"CWE-798 Use of Hard-Coded Credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T15:17:08.719Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-03.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.1"}}},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2026-4832","datePublished":"2026-04-14T15:05:00.845Z","dateReserved":"2026-03-25T14:13:10.490Z","dateUpdated":"2026-04-14T18:16:06.726Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-04-14 16:16:48","lastModifiedDate":"2026-04-17 15:11:35","problem_types":["CWE-798","CWE-798 CWE-798 Use of Hard-Coded Credentials"],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"4832","Ordinal":"1","Title":"CVE-2026-4832","CVE":"CVE-2026-4832","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"4832","Ordinal":"1","NoteData":"CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.","Type":"Description","Title":"CVE-2026-4832"}]}}}