{"api_version":"1","generated_at":"2026-08-24T10:30:27+00:00","cve":"CVE-2026-50064","urls":{"html":"https://cve.report/CVE-2026-50064","api":"https://cve.report/api/cve/CVE-2026-50064.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-50064","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-50064"},"summary":{"title":"CVE-2026-50064","description":"A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-08-11 13:18:58","updated_at":"2026-08-11 18:17:35"},"problem_types":["CWE-787","CWE-787 CWE-787: Out-of-bounds Write"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"7.3","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"7.3","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"baseScore":7.3,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Secondary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"baseScore":7.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-621657.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-621657.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-50064","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-50064","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"Solid Edge SE2025","version":"affected V225.0 Update 15 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Solid Edge SE2026","version":"affected V226.0 Update 7 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"50064","cve":"CVE-2026-50064","epss":"0.001130000","percentile":"0.016590000","score_date":"2026-08-12","updated_at":"2026-08-13 00:04:47"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-50064","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-08-11T18:08:04.058855Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-11T18:08:15.586Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Solid Edge SE2025","vendor":"Siemens","versions":[{"lessThan":"V225.0 Update 15","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Solid Edge SE2026","vendor":"Siemens","versions":[{"lessThan":"V226.0 Update 7","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process."}],"metrics":[{"cvssV3_1":{"baseScore":7.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},{"cvssV4_0":{"baseScore":7.3,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787: Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-11T12:20:20.783Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-621657.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2026-50064","datePublished":"2026-08-11T12:20:20.783Z","dateReserved":"2026-06-03T11:07:02.668Z","dateUpdated":"2026-08-11T18:08:15.586Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-11 13:18:58","lastModifiedDate":"2026-08-11 18:17:35","problem_types":["CWE-787","CWE-787 CWE-787: Out-of-bounds Write"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-11T18:08:04.058855Z","id":"CVE-2026-50064","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"50064","Ordinal":"1","Title":"CVE-2026-50064","CVE":"CVE-2026-50064","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"50064","Ordinal":"1","NoteData":"A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.","Type":"Description","Title":"CVE-2026-50064"}]}}}