{"api_version":"1","generated_at":"2026-07-12T23:06:20+00:00","cve":"CVE-2026-53479","urls":{"html":"https://cve.report/CVE-2026-53479","api":"https://cve.report/api/cve/CVE-2026-53479.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-53479","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-53479"},"summary":{"title":"CVE-2026-53479","description":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to protection mechanism bypass. This is a Critical vulnerability as it allows an attacker to invoke arbitrary command execution with root privileges; so Dell recommends customers to upgrade at the earliest opportunity.","state":"PUBLISHED","assigner":"dell","published_at":"2026-07-07 14:16:32","updated_at":"2026-07-08 19:57:25"},"problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":[{"version":"3.1","source":"security_alert@emc.com","type":"Secondary","score":"7.2","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.2","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","name":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","refsource":"security_alert@emc.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-53479","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-53479","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.8.0.0 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.6.1.20 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 8.3.1.40 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerProtect Data Domain","version":"affected 7.13.1.80 or later semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Dell would like to thank Ahmed Y. Elmogy for reporting these issues.","lang":"en"}],"nvd_cpes":[{"cve_year":"2026","cve_id":"53479","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"data_domain_operating_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"53479","cve":"CVE-2026-53479","epss":"0.011960000","percentile":"0.644050000","score_date":"2026-07-09","updated_at":"2026-07-10 00:08:29"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-53479","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-07-08T03:56:33.302107Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-07-08T13:41:13.329Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerProtect Data Domain","vendor":"Dell","versions":[{"lessThan":"8.8.0.0 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.6.1.20 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"8.3.1.40 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"7.13.1.80 or later","status":"affected","version":"0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"other","value":"Dell would like to thank Ahmed Y. Elmogy for reporting these issues."}],"datePublic":"2026-07-02T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell&nbsp;PowerProtect&nbsp;Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70&nbsp;contain an improper neutralization of special elements used in an OS&nbsp;command ('OS&nbsp;command Injection') vulnerability.&nbsp;A&nbsp;remote&nbsp;high&nbsp;privileged attacker could potentially exploit this vulnerability, leading to&nbsp;protection mechanism bypass.&nbsp;This is a Critical vulnerability as it allows an attacker&nbsp;to&nbsp;invoke arbitrary command execution with root privileges;&nbsp;so&nbsp;Dell recommends customers to upgrade at the earliest opportunity."}],"value":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to protection mechanism bypass. This is a Critical vulnerability as it allows an attacker to invoke arbitrary command execution with root privileges; so Dell recommends customers to upgrade at the earliest opportunity."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-07-07T13:07:26.591Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2026-53479","datePublished":"2026-07-07T13:07:26.591Z","dateReserved":"2026-06-09T17:04:35.250Z","dateUpdated":"2026-07-08T13:41:13.329Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-07-07 14:16:32","lastModifiedDate":"2026-07-08 19:57:25","problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-07-08T03:56:33.302107Z","id":"CVE-2026-53479","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"7.7.1.0","versionEndExcluding":"7.13.1.80","matchCriteriaId":"064F56BA-B974-4133-9DFA-B13D503766AC"},{"vulnerable":true,"criteria":"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"7.14.0.0","versionEndExcluding":"8.3.1.40","matchCriteriaId":"EB4BB568-B169-4202-94E0-8D808419241B"},{"vulnerable":true,"criteria":"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"8.4.0.0","versionEndExcluding":"8.6.1.20","matchCriteriaId":"BA61361F-FED8-4936-A9F6-FFA35BE413F8"},{"vulnerable":true,"criteria":"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"8.7.0.0","versionEndExcluding":"8.8.0.0","matchCriteriaId":"4BA45B0F-6A67-476D-9101-0DDC91B77D51"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"53479","Ordinal":"1","Title":"CVE-2026-53479","CVE":"CVE-2026-53479","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"53479","Ordinal":"1","NoteData":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to protection mechanism bypass. This is a Critical vulnerability as it allows an attacker to invoke arbitrary command execution with root privileges; so Dell recommends customers to upgrade at the earliest opportunity.","Type":"Description","Title":"CVE-2026-53479"}]}}}