{"api_version":"1","generated_at":"2026-07-10T18:13:25+00:00","cve":"CVE-2026-56688","urls":{"html":"https://cve.report/CVE-2026-56688","api":"https://cve.report/api/cve/CVE-2026-56688.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-56688","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-56688"},"summary":{"title":"CVE-2026-56688","description":"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.","state":"PUBLISHED","assigner":"dell","published_at":"2026-07-10 12:17:23","updated_at":"2026-07-10 17:17:01"},"problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":[{"version":"3.1","source":"security_alert@emc.com","type":"Secondary","score":"9.1","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"9.1","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities","name":"https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities","refsource":"security_alert@emc.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-56688","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-56688","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Dell","product":"PowerFlex Manager","version":"affected 5.1.0.1 or later semver","platforms":[]},{"source":"CNA","vendor":"Dell","product":"PowerFlex Manager","version":"affected 4.5.5.2 or later semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-56688","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-07-10T16:49:45.463721Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-07-10T17:01:12.022Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerFlex Manager","vendor":"Dell","versions":[{"lessThan":"5.1.0.1 or later","status":"affected","version":"0","versionType":"semver"},{"lessThan":"4.5.5.2 or later","status":"affected","version":"0","versionType":"semver"}]}],"datePublic":"2026-07-06T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."}],"value":"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-07-10T11:57:41.752Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","assignerShortName":"dell","cveId":"CVE-2026-56688","datePublished":"2026-07-10T11:57:41.752Z","dateReserved":"2026-06-22T17:04:26.238Z","dateUpdated":"2026-07-10T17:01:12.022Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-07-10 12:17:23","lastModifiedDate":"2026-07-10 17:17:01","problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.3,"impactScore":6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-07-10T16:49:45.463721Z","id":"CVE-2026-56688","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"56688","Ordinal":"1","Title":"CVE-2026-56688","CVE":"CVE-2026-56688","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"56688","Ordinal":"1","NoteData":"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.","Type":"Description","Title":"CVE-2026-56688"}]}}}