{"api_version":"1","generated_at":"2026-06-25T03:17:15+00:00","cve":"CVE-2026-5768","urls":{"html":"https://cve.report/CVE-2026-5768","api":"https://cve.report/api/cve/CVE-2026-5768.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-5768","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-5768"},"summary":{"title":"Fourth Frontier Frontier X Mobile Application, Frontier X2 Missing Authentication for Critical Function","description":"The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application.","state":"PUBLISHED","assigner":"icscert","published_at":"2026-05-29 18:17:12","updated_at":"2026-06-16 16:03:27"},"problem_types":["CWE-306","CWE-306 CWE-306"],"metrics":[{"version":"3.1","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://fourthfrontier.com/pages/contact-us","name":"https://fourthfrontier.com/pages/contact-us","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-148-01.json","name":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-148-01.json","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-148-01","name":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-148-01","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-5768","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-5768","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Fourth Frontier","product":"Frontier X Android application","version":"affected 15.0.0 custom","platforms":[]},{"source":"CNA","vendor":"Fourth Frontier","product":"Frontier X IOS application","version":"affected 25.0.0 custom","platforms":[]},{"source":"CNA","vendor":"Fourth Frontier","product":"Frontier X2","version":"affected All versions","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[{"source":"CNA","title":"","value":"Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance: \n https://fourthfrontier.com/pages/contact-us \n\n\n\nFrontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity.","time":"","lang":"en"}],"exploits":[],"credits":[{"source":"CNA","value":"Shakir Zari and Jerin Sunny reported this vulnerability to CISA.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"5768","cve":"CVE-2026-5768","epss":"0.002800000","percentile":"0.195840000","score_date":"2026-06-23","updated_at":"2026-06-24 00:09:26"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-5768","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-29T19:25:07.692084Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-29T19:31:52.111Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Frontier X Android application","vendor":"Fourth Frontier","versions":[{"lessThan":"15.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Frontier X IOS application","vendor":"Fourth Frontier","versions":[{"lessThan":"25.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Frontier X2","vendor":"Fourth Frontier","versions":[{"status":"affected","version":"All versions"}]}],"credits":[{"lang":"en","type":"finder","value":"Shakir Zari and Jerin Sunny reported this vulnerability to CISA."}],"datePublic":"2026-05-28T16:46:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span>The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application.</span>"}],"value":"The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-29T16:58:02.035Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"url":"https://fourthfrontier.com/pages/contact-us"},{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-148-01"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-148-01.json"}],"source":{"advisory":"ICSMA-26-148-01","discovery":"EXTERNAL"},"title":"Fourth Frontier Frontier X Mobile Application, Frontier X2 Missing Authentication for Critical Function","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance:&nbsp;<br><a href=\"https://fourthfrontier.com/pages/contact-us\">https://fourthfrontier.com/pages/contact-us</a></p><p>Frontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity.</p>"}],"value":"Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance: \n https://fourthfrontier.com/pages/contact-us \n\n\n\nFrontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity."}],"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2026-5768","datePublished":"2026-05-29T16:58:02.035Z","dateReserved":"2026-04-07T20:28:13.672Z","dateUpdated":"2026-05-29T19:31:52.111Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-29 18:17:12","lastModifiedDate":"2026-06-16 16:03:27","problem_types":["CWE-306","CWE-306 CWE-306"],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"5768","Ordinal":"1","Title":"Fourth Frontier Frontier X Mobile Application, Frontier X2 Missi","CVE":"CVE-2026-5768","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"5768","Ordinal":"1","NoteData":"The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application.","Type":"Description","Title":"Fourth Frontier Frontier X Mobile Application, Frontier X2 Missi"}]}}}