{"api_version":"1","generated_at":"2026-07-23T10:05:49+00:00","cve":"CVE-2026-61392","urls":{"html":"https://cve.report/CVE-2026-61392","api":"https://cve.report/api/cve/CVE-2026-61392.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-61392","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-61392"},"summary":{"title":"CVE-2026-61392","description":"There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device’s memory.","state":"PUBLISHED","assigner":"hikvision","published_at":"2026-07-22 12:18:18","updated_at":"2026-07-22 20:50:36"},"problem_types":["CWE-200","CWE-200 CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"],"metrics":[{"version":"3.1","source":"hsrc@hikvision.com","type":"Secondary","score":"5.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"5.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/","name":"https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/","refsource":"hsrc@hikvision.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-61392","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-61392","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Hikvision","product":"DS-2CD Series","version":"affected https://www.hikvision.com/en/support/download/firmware/security-firmware-download/ link","platforms":[]},{"source":"CNA","vendor":"Hikvision","product":"DS-2DE Series","version":"affected https://www.hikvision.com/en/support/download/firmware/security-firmware-download/ link","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Daniel Kaye of Inversus Labs","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-61392","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-07-22T12:27:07.318701Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-07-22T12:29:21.886Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"DS-2CD Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]},{"product":"DS-2DE Series","vendor":"Hikvision","versions":[{"status":"affected","version":"https://www.hikvision.com/en/support/download/firmware/security-firmware-download/","versionType":"link"}]}],"credits":[{"lang":"en","type":"finder","value":"Daniel Kaye of Inversus Labs"}],"descriptions":[{"lang":"en","value":"There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device’s memory."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"dateUpdated":"2026-07-22T11:03:11.533Z","orgId":"da451dce-859b-4e51-8b87-9c8b60d19b32","shortName":"hikvision"},"references":[{"url":"https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"}],"x_generator":{"engine":"cveClient/1.0.15"}}},"cveMetadata":{"assignerOrgId":"da451dce-859b-4e51-8b87-9c8b60d19b32","assignerShortName":"hikvision","cveId":"CVE-2026-61392","datePublished":"2026-07-22T11:03:11.533Z","dateReserved":"2026-07-09T05:51:16.531Z","dateUpdated":"2026-07-22T12:29:21.886Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-07-22 12:18:18","lastModifiedDate":"2026-07-22 20:50:36","problem_types":["CWE-200","CWE-200 CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"],"metrics":{"cvssMetricV31":[{"source":"hsrc@hikvision.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-07-22T12:27:07.318701Z","id":"CVE-2026-61392","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"61392","Ordinal":"1","Title":"CVE-2026-61392","CVE":"CVE-2026-61392","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"61392","Ordinal":"1","NoteData":"There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device’s memory.","Type":"Description","Title":"CVE-2026-61392"}]}}}