{"api_version":"1","generated_at":"2026-09-23T14:35:07+00:00","cve":"CVE-2026-71920","urls":{"html":"https://cve.report/CVE-2026-71920","api":"https://cve.report/api/cve/CVE-2026-71920.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-71920","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-71920"},"summary":{"title":"DrayTek VigorSwitch Multiple Models NULL Pointer Dereference via formlogout","description":"Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface.","state":"PUBLISHED","assigner":"VulnCheck","published_at":"2026-08-24 18:17:06","updated_at":"2026-08-26 17:08:22"},"problem_types":["CWE-476","CWE-476 NULL Pointer Dereference"],"metrics":[{"version":"4.0","source":"disclosure@vulncheck.com","type":"Secondary","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","data":{"attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","privilegesRequired":"HIGH","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE"}},{"version":"3.1","source":"disclosure@vulncheck.com","type":"Secondary","score":"4.9","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"4.9","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-null-pointer-dereference-via-formlogout","name":"https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-null-pointer-dereference-via-formlogout","refsource":"disclosure@vulncheck.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/","name":"https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/","refsource":"disclosure@vulncheck.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-71920","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-71920","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2540xs","version":"affected 3.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2540xs","version":"affected 3.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch FX2120","version":"affected 3.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2282x","version":"affected 2.10.6 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2282x","version":"affected 2.10.6 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch Q2300x","version":"affected 2.10.7 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch PQ2300xb","version":"affected 2.10.7 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2542x","version":"affected 3.10.6 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2542x","version":"affected 3.10.6 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2542xh","version":"affected 3.10.6 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch PX2060","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G1280","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P1280","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P1281x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G1282","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P1282","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2121","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2121","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch PQ2121x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch Q2121x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2280x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2280x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch Q2200x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch PQ2200xb","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2100","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2100","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch G2540x","version":"affected 2.9.10 custom","platforms":[]},{"source":"CNA","vendor":"DrayTek Corporation","product":"VigorSwitch P2540x","version":"affected 2.9.10 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Jincheng Wang (@winmt)","lang":"en"},{"source":"CNA","value":"Le Yu (Nanjing University of Posts and Telecommunications)","lang":"en"},{"source":"CNA","value":"Xiapu Luo (The Hong Kong Polytechnic University)","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"71920","cve":"CVE-2026-71920","epss":"0.003920000","percentile":"0.321030000","score_date":"2026-08-27","updated_at":"2026-08-28 00:03:41"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-71920","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-08-24T18:17:16.143303Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-24T18:17:24.678Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"VigorSwitch G2540xs","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2540xs","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch FX2120","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2282x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.10.6","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2282x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.10.6","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch Q2300x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.10.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch PQ2300xb","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.10.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2542x","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.10.6","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2542x","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.10.6","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2542xh","vendor":"DrayTek Corporation","versions":[{"lessThan":"3.10.6","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch PX2060","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G1280","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P1280","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P1281x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G1282","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P1282","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2121","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2121","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch PQ2121x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch Q2121x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2280x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2280x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch Q2200x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch PQ2200xb","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2100","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2100","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch G2540x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VigorSwitch P2540x","vendor":"DrayTek Corporation","versions":[{"lessThan":"2.9.10","status":"affected","version":"0","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:draytek:vigorswitch_g2540xs_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_p2540xs_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_fx2120_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_g1282_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_p1282_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_g2121_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_pq2121x_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_q2121x_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_g2280x_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_p2280x_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_q2200x_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_pq2200xb_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_g2100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true},{"criteria":"cpe:2.3:o:draytek:vigorswitch_p2100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.9.10","vulnerable":true}],"negate":false,"operator":"OR"}]}],"credits":[{"lang":"en","type":"finder","value":"Jincheng Wang (@winmt)"},{"lang":"en","type":"finder","value":"Le Yu (Nanjing University of Posts and Telecommunications)"},{"lang":"en","type":"finder","value":"Xiapu Luo (The Hong Kong Polytechnic University)"}],"datePublic":"2026-08-24T00:00:00.000Z","descriptions":[{"lang":"en","value":"Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface."}],"metrics":[{"cvssV4_0":{"attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","privilegesRequired":"HIGH","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE"},"format":"CVSS"},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-476","description":"NULL Pointer Dereference","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-24T17:07:50.273Z","orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","shortName":"VulnCheck"},"references":[{"tags":["vendor-advisory"],"url":"https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/"},{"name":"VulnCheck Advisory: DrayTek VigorSwitch Multiple Models NULL Pointer Dereference via formlogout","tags":["third-party-advisory"],"url":"https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-null-pointer-dereference-via-formlogout"}],"title":"DrayTek VigorSwitch Multiple Models NULL Pointer Dereference via formlogout","x_generator":{"engine":"vulncheck-endgame"}}},"cveMetadata":{"assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","assignerShortName":"VulnCheck","cveId":"CVE-2026-71920","datePublished":"2026-08-24T17:07:50.273Z","dateReserved":"2026-08-08T16:37:44.518Z","dateUpdated":"2026-08-24T18:17:24.678Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-24 18:17:06","lastModifiedDate":"2026-08-26 17:08:22","problem_types":["CWE-476","CWE-476 NULL Pointer Dereference"],"metrics":{"cvssMetricV40":[{"source":"disclosure@vulncheck.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"disclosure@vulncheck.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-24T18:17:16.143303Z","id":"CVE-2026-71920","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"71920","Ordinal":"1","Title":"DrayTek VigorSwitch Multiple Models NULL Pointer Dereference via","CVE":"CVE-2026-71920","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"71920","Ordinal":"1","NoteData":"Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface.","Type":"Description","Title":"DrayTek VigorSwitch Multiple Models NULL Pointer Dereference via"}]}}}