{"api_version":"1","generated_at":"2026-09-11T08:06:39+00:00","cve":"CVE-2026-73731","urls":{"html":"https://cve.report/CVE-2026-73731","api":"https://cve.report/api/cve/CVE-2026-73731.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-73731","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-73731"},"summary":{"title":"Unauthenticated Reflected Cross-Site Scripting (XSS) Vulnerability in HPE Networking Fabric Composer Web-Based Management Interface","description":"A vulnerability in the web-based management interface of HPE Networking Fabric Composer could allow an unauthenticated remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.","state":"PUBLISHED","assigner":"hpe","published_at":"2026-09-01 20:17:20","updated_at":"2026-09-03 15:12:59"},"problem_types":["CWE-79","CWE-79 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"],"metrics":[{"version":"3.1","source":"security-alert@hpe.com","type":"Secondary","score":"6.1","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.1","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"}}],"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05133en_us&docLocale=en_US","name":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05133en_us&docLocale=en_US","refsource":"security-alert@hpe.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-73731","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-73731","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Hewlett Packard Enterprise (HPE)","product":"Fabric Composer","version":"affected 7.0.0 7.3.3 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"This vulnerability was discovered by internal security research at HPE Networking.","lang":"en"}],"nvd_cpes":[{"cve_year":"2026","cve_id":"73731","vulnerable":"1","versionEndIncluding":"7.3.3","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"arubanetworks","cpe5":"fabric_composer","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"73731","cve":"CVE-2026-73731","epss":"0.001930000","percentile":"0.090290000","score_date":"2026-09-07","updated_at":"2026-09-08 00:05:28"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-73731","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-09-02T16:19:58.953784Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-02T18:57:38.467Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"affected","product":"Fabric Composer","vendor":"Hewlett Packard Enterprise (HPE)","versions":[{"lessThanOrEqual":"7.3.3","status":"affected","version":"7.0.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"reporter","value":"This vulnerability was discovered by internal security research at HPE Networking."}],"descriptions":[{"lang":"en","value":"A vulnerability in the web-based management interface of HPE Networking Fabric Composer could allow an unauthenticated remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"dateUpdated":"2026-09-01T20:24:40.874Z","orgId":"eb103674-0d28-4225-80f8-39fb86215de0","shortName":"hpe"},"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05133en_us&docLocale=en_US"}],"source":{"advisory":"HPESBNW05133","discovery":"INTERNAL"},"title":"Unauthenticated Reflected Cross-Site Scripting (XSS) Vulnerability in HPE Networking Fabric Composer Web-Based Management Interface","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"eb103674-0d28-4225-80f8-39fb86215de0","assignerShortName":"hpe","cveId":"CVE-2026-73731","datePublished":"2026-09-01T19:47:09.945Z","dateReserved":"2026-08-13T16:37:26.896Z","dateUpdated":"2026-09-02T18:57:38.467Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-01 20:17:20","lastModifiedDate":"2026-09-03 15:12:59","problem_types":["CWE-79","CWE-79 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"],"metrics":{"cvssMetricV31":[{"source":"security-alert@hpe.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-02T16:19:58.953784Z","id":"CVE-2026-73731","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:fabric_composer:*:*:*:*:*:*:*:*","versionEndIncluding":"7.3.3","matchCriteriaId":"9D4FBA23-A05C-4C71-9AC4-67F7F68C7A35"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"73731","Ordinal":"1","Title":"Unauthenticated Reflected Cross-Site Scripting (XSS) Vulnerabili","CVE":"CVE-2026-73731","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"73731","Ordinal":"1","NoteData":"A vulnerability in the web-based management interface of HPE Networking Fabric Composer could allow an unauthenticated remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.","Type":"Description","Title":"Unauthenticated Reflected Cross-Site Scripting (XSS) Vulnerabili"}]}}}