{"api_version":"1","generated_at":"2026-08-22T04:27:12+00:00","cve":"CVE-2026-76329","urls":{"html":"https://cve.report/CVE-2026-76329","api":"https://cve.report/api/cve/CVE-2026-76329.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-76329","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-76329"},"summary":{"title":"SPL Injection through Monitoring Console Dashboard Inputs in Splunk Enterprise","description":"In Splunk Enterprise versions below 10.4.2, 10.2.6, 10.0.9, and 9.4.14, an unauthenticated user could trick a user who holds the \"admin\" Splunk role into opening a crafted link to Monitoring Console. When that user opens the link, Splunk Enterprise runs attacker-controlled Search Processing Language (SPL) using the permissions of that user. The injected SPL could expose data available to that user or modify lookup data. The vulnerability is possible because Monitoring Console does not sufficiently validate data used to build dashboard searches. The vulnerability requires the attacker to phish the user by tricking them into opening the crafted link. The unauthenticated user should not be able to exploit the vulnerability at will.","state":"PUBLISHED","assigner":"cisco","published_at":"2026-08-19 22:17:17","updated_at":"2026-08-21 19:15:55"},"problem_types":["CWE-943","CWE-943 The application generates a query intended to access or manipulate data in a data store such as a database, but it does not neutralize or incorrectly neutralizes special elements that can modify the intended logic of the query."],"metrics":[{"version":"3.1","source":"psirt@cisco.com","type":"Primary","score":"6.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","baseScore":6.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","data":{"baseScore":6.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","version":"3.1"}}],"references":[{"url":"https://advisory.splunk.com/advisories/SVD-2026-0801","name":"https://advisory.splunk.com/advisories/SVD-2026-0801","refsource":"psirt@cisco.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-76329","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-76329","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Splunk","product":"Splunk Enterprise","version":"affected 10.4 10.4.2 custom","platforms":[]},{"source":"CNA","vendor":"Splunk","product":"Splunk Enterprise","version":"affected 10.2 10.2.6 custom","platforms":[]},{"source":"CNA","vendor":"Splunk","product":"Splunk Enterprise","version":"affected 10.0 10.0.9 custom","platforms":[]},{"source":"CNA","vendor":"Splunk","product":"Splunk Enterprise","version":"affected 9.4 9.4.14 custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Upgrade Splunk Enterprise to versions 10.4.2, 10.2.6, 10.0.9, and 9.4.14, or higher.","time":"","lang":"en"}],"workarounds":[{"source":"CNA","title":"","value":"The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround. See [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/configuration-file-reference/10.4.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web.","time":"","lang":"en"}],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2026","cve_id":"76329","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"splunk","cpe5":"splunk","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"enterprise","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"76329","cve":"CVE-2026-76329","epss":"0.001950000","percentile":"0.095480000","score_date":"2026-08-21","updated_at":"2026-08-22 00:12:50"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"product":"Splunk Enterprise","vendor":"Splunk","versions":[{"lessThan":"10.4.2","status":"affected","version":"10.4","versionType":"custom"},{"lessThan":"10.2.6","status":"affected","version":"10.2","versionType":"custom"},{"lessThan":"10.0.9","status":"affected","version":"10.0","versionType":"custom"},{"lessThan":"9.4.14","status":"affected","version":"9.4","versionType":"custom"}]}],"datePublic":"2026-08-19T00:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/markdown","value":"In Splunk Enterprise versions below 10.4.2, 10.2.6, 10.0.9, and 9.4.14, an unauthenticated user could trick a user who holds the \"admin\" Splunk role into opening a crafted link to Monitoring Console. When that user opens the link, Splunk Enterprise runs attacker-controlled Search Processing Language (SPL) using the permissions of that user. The injected SPL could expose data available to that user or modify lookup data. The vulnerability is possible because Monitoring Console does not sufficiently validate data used to build dashboard searches. The vulnerability requires the attacker to phish the user by tricking them into opening the crafted link. The unauthenticated user should not be able to exploit the vulnerability at will."}],"value":"In Splunk Enterprise versions below 10.4.2, 10.2.6, 10.0.9, and 9.4.14, an unauthenticated user could trick a user who holds the \"admin\" Splunk role into opening a crafted link to Monitoring Console. When that user opens the link, Splunk Enterprise runs attacker-controlled Search Processing Language (SPL) using the permissions of that user. The injected SPL could expose data available to that user or modify lookup data. The vulnerability is possible because Monitoring Console does not sufficiently validate data used to build dashboard searches. The vulnerability requires the attacker to phish the user by tricking them into opening the crafted link. The unauthenticated user should not be able to exploit the vulnerability at will."}],"metrics":[{"cvssV3_1":{"baseScore":6.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-943","description":"The application generates a query intended to access or manipulate data in a data store such as a database, but it does not neutralize or incorrectly neutralizes special elements that can modify the intended logic of the query.","lang":"en","type":"cwe"}]}],"providerMetadata":{"dateUpdated":"2026-08-19T21:34:32.243Z","orgId":"d1c1063e-7a18-46af-9102-31f8928bc633","shortName":"cisco"},"references":[{"url":"https://advisory.splunk.com/advisories/SVD-2026-0801"}],"solutions":[{"lang":"en","value":"Upgrade Splunk Enterprise to versions 10.4.2, 10.2.6, 10.0.9, and 9.4.14, or higher."}],"source":{"advisory":"SVD-2026-0801"},"title":"SPL Injection through Monitoring Console Dashboard Inputs in Splunk Enterprise","workarounds":[{"lang":"en","value":"The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround. See [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/configuration-file-reference/10.4.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web."}]}},"cveMetadata":{"assignerOrgId":"d1c1063e-7a18-46af-9102-31f8928bc633","assignerShortName":"cisco","cveId":"CVE-2026-76329","datePublished":"2026-08-19T21:34:32.243Z","dateReserved":"2026-08-19T12:02:03.626Z","dateUpdated":"2026-08-19T21:34:32.243Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-19 22:17:17","lastModifiedDate":"2026-08-21 19:15:55","problem_types":["CWE-943","CWE-943 The application generates a query intended to access or manipulate data in a data store such as a database, but it does not neutralize or incorrectly neutralizes special elements that can modify the intended logic of the query."],"metrics":{"cvssMetricV31":[{"source":"psirt@cisco.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L","baseScore":6.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":1.6,"impactScore":4.7}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*","versionStartIncluding":"9.4.0","versionEndExcluding":"9.4.14","matchCriteriaId":"E180CC4C-5B8B-4D69-8535-93DCF3510119"},{"vulnerable":true,"criteria":"cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*","versionStartIncluding":"10.0.0","versionEndExcluding":"10.0.9","matchCriteriaId":"0FD75354-A6EE-49F9-9B8A-31287A845CFB"},{"vulnerable":true,"criteria":"cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*","versionStartIncluding":"10.2.0","versionEndExcluding":"10.2.6","matchCriteriaId":"C8FDA841-04BC-404C-B56D-7869CBD8B56C"},{"vulnerable":true,"criteria":"cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*","versionStartIncluding":"10.4.0","versionEndExcluding":"10.4.2","matchCriteriaId":"209C1DE6-893D-424D-B103-B64A314AD8DC"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"76329","Ordinal":"1","Title":"SPL Injection through Monitoring Console Dashboard Inputs in Spl","CVE":"CVE-2026-76329","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"76329","Ordinal":"1","NoteData":"In Splunk Enterprise versions below 10.4.2, 10.2.6, 10.0.9, and 9.4.14, an unauthenticated user could trick a user who holds the \"admin\" Splunk role into opening a crafted link to Monitoring Console. When that user opens the link, Splunk Enterprise runs attacker-controlled Search Processing Language (SPL) using the permissions of that user. The injected SPL could expose data available to that user or modify lookup data. The vulnerability is possible because Monitoring Console does not sufficiently validate data used to build dashboard searches. The vulnerability requires the attacker to phish the user by tricking them into opening the crafted link. The unauthenticated user should not be able to exploit the vulnerability at will.","Type":"Description","Title":"SPL Injection through Monitoring Console Dashboard Inputs in Spl"}]}}}