{"api_version":"1","generated_at":"2026-09-23T00:05:24+00:00","cve":"CVE-2026-76678","urls":{"html":"https://cve.report/CVE-2026-76678","api":"https://cve.report/api/cve/CVE-2026-76678.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-76678","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-76678"},"summary":{"title":"Authenticated Command Injection Vulnerability leads to Remote Code Execution in EdgeConnect SD-WAN Gateways","description":"A vulnerability in the API endpoint of HPE Networking EdgeConnect SD-WAN Gateways could allow a low-privilege authenticated remote attacker to escalate privileges. Successful exploitation of this vulnerability may enable the attacker to execute arbitrary system commands with root privileges on the underlying operating system.","state":"PUBLISHED","assigner":"hpe","published_at":"2026-09-15 20:17:49","updated_at":"2026-09-21 20:17:30"},"problem_types":["CWE-269","CWE-269 CWE-269 Improper Privilege Management"],"metrics":[{"version":"3.1","source":"security-alert@hpe.com","type":"Secondary","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us&docLocale=en_US","name":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us&docLocale=en_US","refsource":"security-alert@hpe.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-76678","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-76678","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Hewlett Packard Enterprise (HPE)","product":"EdgeConnect SD-WAN Gateways","version":"affected 9.7.0.0 9.7.0.0 semver","platforms":[]},{"source":"CNA","vendor":"Hewlett Packard Enterprise (HPE)","product":"EdgeConnect SD-WAN Gateways","version":"affected 9.6.0.0 9.6.3.1 semver","platforms":[]},{"source":"CNA","vendor":"Hewlett Packard Enterprise (HPE)","product":"EdgeConnect SD-WAN Gateways","version":"affected 9.5.0.0 9.5.8.1 semver","platforms":[]},{"source":"CNA","vendor":"Hewlett Packard Enterprise (HPE)","product":"EdgeConnect SD-WAN Gateways","version":"affected 9.4.0.0 9.4.8.2 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Internal security research (HPE Networking).","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"76678","cve":"CVE-2026-76678","epss":"0.007180000","percentile":"0.519650000","score_date":"2026-09-21","updated_at":"2026-09-22 00:03:15"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-76678","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-21T19:53:28.226364Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-269","description":"CWE-269 Improper Privilege Management","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-21T19:53:47.355Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"affected","product":"EdgeConnect SD-WAN Gateways","vendor":"Hewlett Packard Enterprise (HPE)","versions":[{"lessThanOrEqual":"9.7.0.0","status":"affected","version":"9.7.0.0","versionType":"semver"},{"lessThanOrEqual":"9.6.3.1","status":"affected","version":"9.6.0.0","versionType":"semver"},{"lessThanOrEqual":"9.5.8.1","status":"affected","version":"9.5.0.0","versionType":"semver"},{"lessThanOrEqual":"9.4.8.2","status":"affected","version":"9.4.0.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"reporter","value":"Internal security research (HPE Networking)."}],"descriptions":[{"lang":"en","value":"A vulnerability in the API endpoint of HPE Networking EdgeConnect SD-WAN Gateways could allow a low-privilege authenticated remote attacker to escalate privileges. Successful exploitation of this vulnerability may enable the attacker to execute arbitrary system commands with root privileges on the underlying operating system."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"dateUpdated":"2026-09-15T19:23:38.640Z","orgId":"eb103674-0d28-4225-80f8-39fb86215de0","shortName":"hpe"},"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us&docLocale=en_US"}],"source":{"advisory":"HPESBNW05135","discovery":"INTERNAL"},"title":"Authenticated Command Injection Vulnerability leads to Remote Code Execution in EdgeConnect SD-WAN Gateways","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"eb103674-0d28-4225-80f8-39fb86215de0","assignerShortName":"hpe","cveId":"CVE-2026-76678","datePublished":"2026-09-15T19:23:38.640Z","dateReserved":"2026-08-19T16:11:18.067Z","dateUpdated":"2026-09-21T19:53:47.355Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-15 20:17:49","lastModifiedDate":"2026-09-21 20:17:30","problem_types":["CWE-269","CWE-269 CWE-269 Improper Privilege Management"],"metrics":{"cvssMetricV31":[{"source":"security-alert@hpe.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-21T19:53:28.226364Z","id":"CVE-2026-76678","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"76678","Ordinal":"1","Title":"Authenticated Command Injection Vulnerability leads to Remote Co","CVE":"CVE-2026-76678","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"76678","Ordinal":"1","NoteData":"A vulnerability in the API endpoint of HPE Networking EdgeConnect SD-WAN Gateways could allow a low-privilege authenticated remote attacker to escalate privileges. Successful exploitation of this vulnerability may enable the attacker to execute arbitrary system commands with root privileges on the underlying operating system.","Type":"Description","Title":"Authenticated Command Injection Vulnerability leads to Remote Co"}]}}}