{"api_version":"1","generated_at":"2026-11-16T17:34:39+00:00","cve":"CVE-2026-77873","urls":{"html":"https://cve.report/CVE-2026-77873","api":"https://cve.report/api/cve/CVE-2026-77873.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-77873","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-77873"},"summary":{"title":"CVE-2026-77873","description":"An improper permissions vulnerability was reported in Lenovo System Update that could allow a local authenticated user to execute code with elevated privileges.","state":"PUBLISHED","assigner":"lenovo","published_at":"2026-11-11 17:17:19","updated_at":"2026-11-12 22:09:39"},"problem_types":["CWE-276","CWE-276 CWE-276: Incorrect Default Permissions"],"metrics":[{"version":"4.0","source":"psirt@lenovo.com","type":"Secondary","score":"7","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"7","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"psirt@lenovo.com","type":"Primary","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://support.lenovo.com/us/en/product_security/LEN-232748","name":"https://support.lenovo.com/us/en/product_security/LEN-232748","refsource":"psirt@lenovo.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://support.lenovo.com/us/en/downloads/ds012808","name":"https://support.lenovo.com/us/en/downloads/ds012808","refsource":"psirt@lenovo.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-77873","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-77873","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Lenovo","product":"System Update","version":"affected 5.08.03.59 custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"As of October 31, 2026, Lenovo System Update has reached end of support status, and no further updates will be released to address these vulnerabilities.  Lenovo recommends that users uninstall Lenovo System Update as soon as possible and migrate to Lenovo Commercial Vantage ( Lenovo Commercial Vantage - Lenovo Support US https://support.lenovo.com/us/en/solutions/hf003321 ).","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Lenovo thanks sf0rn for reporting this vulnerability.","lang":"en"},{"source":"CNA","value":"Lenovo thanks Nicholas Ineson – Forefront IT Security Services Ltd for subsequently reporting this vulnerability.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"77873","cve":"CVE-2026-77873","epss":"0.001290000","percentile":"0.025860000","score_date":"2026-11-15","updated_at":"2026-11-16 00:06:42"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"System Update","vendor":"Lenovo","versions":[{"lessThanOrEqual":"5.08.03.59","status":"affected","version":"0","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:lenovo:system_update:*:*:*:*:*:*:*:*","versionEndIncluding":"5.08.03.59","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Lenovo thanks sf0rn for reporting this vulnerability."},{"lang":"en","type":"finder","value":"Lenovo thanks Nicholas Ineson – Forefront IT Security Services Ltd for subsequently reporting this vulnerability."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An improper permissions vulnerability was reported in Lenovo System Update that could allow a local authenticated user to execute code with elevated privileges."}],"value":"An improper permissions vulnerability was reported in Lenovo System Update that could allow a local authenticated user to execute code with elevated privileges."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-276","description":"CWE-276: Incorrect Default Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-11T16:15:32.544Z","orgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","shortName":"lenovo"},"references":[{"tags":["vendor-advisory"],"url":"https://support.lenovo.com/us/en/product_security/LEN-232748"},{"tags":["product"],"url":"https://support.lenovo.com/us/en/downloads/ds012808"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>As of October 31, 2026, Lenovo System Update has reached end of support status, and no further updates will be released to address these vulnerabilities. &nbsp;Lenovo recommends that users uninstall Lenovo System Update as soon as possible and migrate to Lenovo Commercial Vantage (<a href=\"https://support.lenovo.com/us/en/solutions/hf003321\" target=\"_blank\" rel=\"nofollow noopener\" title=\"Follow link\">Lenovo Commercial Vantage - Lenovo Support US</a>).</p>"}],"value":"As of October 31, 2026, Lenovo System Update has reached end of support status, and no further updates will be released to address these vulnerabilities.  Lenovo recommends that users uninstall Lenovo System Update as soon as possible and migrate to Lenovo Commercial Vantage ( Lenovo Commercial Vantage - Lenovo Support US https://support.lenovo.com/us/en/solutions/hf003321 )."}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.0-beta"}}},"cveMetadata":{"assignerOrgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","assignerShortName":"lenovo","cveId":"CVE-2026-77873","datePublished":"2026-11-11T16:15:32.544Z","dateReserved":"2026-08-21T15:10:58.579Z","dateUpdated":"2026-11-11T16:15:32.544Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-11 17:17:19","lastModifiedDate":"2026-11-12 22:09:39","problem_types":["CWE-276","CWE-276 CWE-276: Incorrect Default Permissions"],"metrics":{"cvssMetricV40":[{"source":"psirt@lenovo.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"psirt@lenovo.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"77873","Ordinal":"1","Title":"CVE-2026-77873","CVE":"CVE-2026-77873","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"77873","Ordinal":"1","NoteData":"An improper permissions vulnerability was reported in Lenovo System Update that could allow a local authenticated user to execute code with elevated privileges.","Type":"Description","Title":"CVE-2026-77873"}]}}}