{"api_version":"1","generated_at":"2026-10-22T18:25:35+00:00","cve":"CVE-2026-79316","urls":{"html":"https://cve.report/CVE-2026-79316","api":"https://cve.report/api/cve/CVE-2026-79316.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-79316","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-79316"},"summary":{"title":"CVE-2026-79316","description":"An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.","state":"PUBLISHED","assigner":"mitre","published_at":"2026-09-21 21:17:12","updated_at":"2026-09-22 20:00:03"},"problem_types":["CWE-284","n/a","CWE-284 CWE-284 Improper Access Control"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"}}],"references":[{"url":"https://github.com/vaxilu/x-ui","name":"https://github.com/vaxilu/x-ui","refsource":"cve@mitre.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/lichoin/TraceLoom/blob/main/CVEs/CVE-2026-79316.md","name":"https://github.com/lichoin/TraceLoom/blob/main/CVEs/CVE-2026-79316.md","refsource":"cve@mitre.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-79316","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-79316","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"79316","cve":"CVE-2026-79316","epss":"0.002340000","percentile":"0.146470000","score_date":"2026-09-23","updated_at":"2026-09-24 00:07:16"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","version":"3.1"}},{"other":{"content":{"id":"CVE-2026-79316","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-09-22T14:46:38.598501Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284 Improper Access Control","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-22T14:47:48.679Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2026-09-21T20:24:22.891Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://github.com/vaxilu/x-ui"},{"url":"https://github.com/lichoin/TraceLoom/blob/main/CVEs/CVE-2026-79316.md"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2026-79316","datePublished":"2026-09-21T00:00:00.000Z","dateReserved":"2026-08-25T00:00:00.000Z","dateUpdated":"2026-09-22T14:47:48.679Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-21 21:17:12","lastModifiedDate":"2026-09-22 20:00:03","problem_types":["CWE-284","n/a","CWE-284 CWE-284 Improper Access Control"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":4.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-22T14:46:38.598501Z","id":"CVE-2026-79316","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"79316","Ordinal":"1","Title":"CVE-2026-79316","CVE":"CVE-2026-79316","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"79316","Ordinal":"1","NoteData":"An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.","Type":"Description","Title":"CVE-2026-79316"}]}}}