{"api_version":"1","generated_at":"2026-07-09T19:38:38+00:00","cve":"CVE-2026-8108","urls":{"html":"https://cve.report/CVE-2026-8108","api":"https://cve.report/api/cve/CVE-2026-8108.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-8108","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-8108"},"summary":{"title":"Fuji Electric Tellus Exposed Dangerous Method or Function","description":"The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions.","state":"PUBLISHED","assigner":"icscert","published_at":"2026-05-12 23:16:19","updated_at":"2026-05-13 15:52:56"},"problem_types":["CWE-749","CWE-749 CWE-749"],"metrics":[{"version":"3.1","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-01.json","name":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-01.json","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-01","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-01","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-8108","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-8108","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Fuji Electric","product":"Tellus","version":"affected 5.0.2","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[{"source":"CNA","title":"","value":"Fuji Electric recommends that Tellus be installed only with administrator privileges.","time":"","lang":"en"}],"exploits":[],"credits":[{"source":"CNA","value":"Kim Myung-gyu of Trend Micro Zero Day Initiative reported this vulnerability to CISA.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"8108","cve":"CVE-2026-8108","epss":"0.000050000","percentile":"0.002620000","score_date":"2026-05-20","updated_at":"2026-05-21 00:09:24"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-8108","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-13T01:38:52.768933Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-13T01:39:00.948Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Tellus","vendor":"Fuji Electric","versions":[{"status":"affected","version":"5.0.2"}]}],"credits":[{"lang":"en","type":"finder","value":"Kim Myung-gyu of Trend Micro Zero Day Initiative reported this vulnerability to CISA."}],"datePublic":"2026-05-12T22:26:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions."}],"value":"The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-749","description":"CWE-749","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-12T22:29:53.239Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-01"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-01.json"}],"source":{"advisory":"ICSA-26-132-01","discovery":"EXTERNAL"},"title":"Fuji Electric Tellus Exposed Dangerous Method or Function","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Fuji Electric recommends that Tellus be installed only with administrator privileges."}],"value":"Fuji Electric recommends that Tellus be installed only with administrator privileges."}],"x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2026-8108","datePublished":"2026-05-12T22:29:53.239Z","dateReserved":"2026-05-07T15:18:17.964Z","dateUpdated":"2026-05-13T01:39:00.948Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-12 23:16:19","lastModifiedDate":"2026-05-13 15:52:56","problem_types":["CWE-749","CWE-749 CWE-749"],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"8108","Ordinal":"1","Title":"Fuji Electric Tellus Exposed Dangerous Method or Function","CVE":"CVE-2026-8108","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"8108","Ordinal":"1","NoteData":"The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions.","Type":"Description","Title":"Fuji Electric Tellus Exposed Dangerous Method or Function"}]}}}