{"api_version":"1","generated_at":"2026-09-14T14:29:07+00:00","cve":"CVE-2026-82791","urls":{"html":"https://cve.report/CVE-2026-82791","api":"https://cve.report/api/cve/CVE-2026-82791.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-82791","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-82791"},"summary":{"title":"CVE-2026-82791","description":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.","state":"PUBLISHED","assigner":"jpcert","published_at":"2026-09-14 07:17:21","updated_at":"2026-09-14 13:18:57"},"problem_types":["CWE-78","CWE-78 Improper neutralization of special elements used in an OS command ('OS Command Injection')"],"metrics":[{"version":"4.0","source":"vultures@jpcert.or.jp","type":"Secondary","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"baseScore":8.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"vultures@jpcert.or.jp","type":"Secondary","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":8.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://jvn.jp/en/vu/JVNVU90314828/","name":"https://jvn.jp/en/vu/JVNVU90314828/","refsource":"vultures@jpcert.or.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf","name":"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf","refsource":"vultures@jpcert.or.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-82791","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-82791","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Contec Co., Ltd.","product":"CAN-2-WF","version":"affected 2.20 semver","platforms":[]},{"source":"CNA","vendor":"Contec Co., Ltd.","product":"CAN-2-USB","version":"affected 2.20 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-82791","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-14T12:07:44.065201Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-14T12:07:55.617Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"CAN-2-WF","vendor":"Contec Co., Ltd.","versions":[{"lessThan":"2.20","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CAN-2-USB","vendor":"Contec Co., Ltd.","versions":[{"lessThan":"2.20","status":"affected","version":"0","versionType":"semver"}]}],"descriptions":[{"lang":"en","value":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."}],"metrics":[{"cvssV3_1":{"baseScore":8.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en-US","value":"GENERAL"}]},{"cvssV4_0":{"baseScore":8.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"format":"CVSS","scenarios":[{"lang":"en-US","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"Improper neutralization of special elements used in an OS command ('OS Command Injection')","lang":"en-US","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-14T06:45:22.083Z","orgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","shortName":"jpcert"},"references":[{"url":"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"},{"url":"https://jvn.jp/en/vu/JVNVU90314828/"}]}},"cveMetadata":{"assignerOrgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","assignerShortName":"jpcert","cveId":"CVE-2026-82791","datePublished":"2026-09-14T06:45:22.083Z","dateReserved":"2026-08-31T02:30:58.279Z","dateUpdated":"2026-09-14T12:07:55.617Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-14 07:17:21","lastModifiedDate":"2026-09-14 13:18:57","problem_types":["CWE-78","CWE-78 Improper neutralization of special elements used in an OS command ('OS Command Injection')"],"metrics":{"cvssMetricV40":[{"source":"vultures@jpcert.or.jp","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"vultures@jpcert.or.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-14T12:07:44.065201Z","id":"CVE-2026-82791","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"82791","Ordinal":"1","Title":"CVE-2026-82791","CVE":"CVE-2026-82791","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"82791","Ordinal":"1","NoteData":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.","Type":"Description","Title":"CVE-2026-82791"}]}}}