{"api_version":"1","generated_at":"2026-11-23T04:49:21+00:00","cve":"CVE-2026-82949","urls":{"html":"https://cve.report/CVE-2026-82949","api":"https://cve.report/api/cve/CVE-2026-82949.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-82949","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-82949"},"summary":{"title":"Occupancy monitoring via unencrypted RF communication","description":"The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.","state":"PUBLISHED","assigner":"ENISA","published_at":"2026-11-19 11:17:08","updated_at":"2026-11-19 16:22:00"},"problem_types":["CWE-319","CWE-319 CWE-319: Cleartext Transmission of Sensitive Information"],"metrics":[{"version":"4.0","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","score":"7.1","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"7.1","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":7.1,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c","name":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c","refsource":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-82949","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-82949","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Onyx Cookware ApS","product":"Nexsmart Guardian 2 (Alarm system)","version":"affected semver","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Elias Lindström","lang":"en"},{"source":"CNA","value":"CERT-SE","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-82949","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-11-19T15:10:44.258774Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-19T15:10:55.174Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"affected","product":"Nexsmart Guardian 2 (Alarm system)","vendor":"Onyx Cookware ApS","versions":[{"status":"affected","version":"0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Elias Lindström"},{"lang":"en","type":"coordinator","value":"CERT-SE"}],"datePublic":"2026-11-19T09:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.</p>"}],"value":"The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":7.1,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319: Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-19T10:32:13.090Z","orgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","shortName":"ENISA"},"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<i><span>Nexsmart reported suspending sales and described a phase-out of the current Guardian models.&nbsp;</span><span>If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.</span></i>"}],"value":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance."}],"source":{"discovery":"UNKNOWN"},"title":"Occupancy monitoring via unencrypted RF communication","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","assignerShortName":"ENISA","cveId":"CVE-2026-82949","datePublished":"2026-11-19T10:32:13.090Z","dateReserved":"2026-08-31T12:26:22.054Z","dateUpdated":"2026-11-19T15:10:55.174Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-19 11:17:08","lastModifiedDate":"2026-11-19 16:22:00","problem_types":["CWE-319","CWE-319 CWE-319: Cleartext Transmission of Sensitive Information"],"metrics":{"cvssMetricV40":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-19T15:10:44.258774Z","id":"CVE-2026-82949","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"82949","Ordinal":"1","Title":"Occupancy monitoring via unencrypted RF communication","CVE":"CVE-2026-82949","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"82949","Ordinal":"1","NoteData":"The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.","Type":"Description","Title":"Occupancy monitoring via unencrypted RF communication"}]}}}