{"api_version":"1","generated_at":"2026-11-28T16:10:23+00:00","cve":"CVE-2026-82950","urls":{"html":"https://cve.report/CVE-2026-82950","api":"https://cve.report/api/cve/CVE-2026-82950.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-82950","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-82950"},"summary":{"title":"Alert suppression through deauthentication-induced notification failure","description":"The device only supports Wi-Fi protocols vulnerable to\ndeauthentication attacks (WEP/WPA/WPA2). Should any event which would typically\nbe logged to the user’s mobile device (such as arming or disarming the alarm or\nany tamper events) be incurred whilst the device is temporarily disconnected\nfrom its Wi-Fi network (such as via a deauthentication attack), those alerts\nwill not be sent even after connection is regained.","state":"PUBLISHED","assigner":"ENISA","published_at":"2026-11-19 11:17:08","updated_at":"2026-11-24 17:50:43"},"problem_types":["CWE-390","CWE-390 CWE-390: Detection of Error Condition Without Action"],"metrics":[{"version":"4.0","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","score":"7.1","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"7.1","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":7.1,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c","name":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c","refsource":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-82950","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-82950","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Onyx Cookware ApS","product":"Nexsmart Guardian 2 (Alarm system)","version":"affected semver","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Elias Lindström","lang":"en"},{"source":"CNA","value":"CERT-SE","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"82950","cve":"CVE-2026-82950","epss":"0.002980000","percentile":"0.148050000","score_date":"2026-11-25","updated_at":"2026-11-26 00:09:07"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-82950","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-11-19T16:52:42.933494Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-19T16:54:54.934Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"affected","product":"Nexsmart Guardian 2 (Alarm system)","vendor":"Onyx Cookware ApS","versions":[{"status":"affected","version":"0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Elias Lindström"},{"lang":"en","type":"coordinator","value":"CERT-SE"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>The device only supports Wi-Fi protocols vulnerable to\ndeauthentication attacks (WEP/WPA/WPA2). Should any event which would typically\nbe logged to the user’s mobile device (such as arming or disarming the alarm or\nany tamper events) be incurred whilst the device is temporarily disconnected\nfrom its Wi-Fi network (such as via a deauthentication attack), those alerts\nwill not be sent even after connection is regained.</p>"}],"value":"The device only supports Wi-Fi protocols vulnerable to\ndeauthentication attacks (WEP/WPA/WPA2). Should any event which would typically\nbe logged to the user’s mobile device (such as arming or disarming the alarm or\nany tamper events) be incurred whilst the device is temporarily disconnected\nfrom its Wi-Fi network (such as via a deauthentication attack), those alerts\nwill not be sent even after connection is regained."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":7.1,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-390","description":"CWE-390: Detection of Error Condition Without Action","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-19T10:33:17.907Z","orgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","shortName":"ENISA"},"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<i><span>Nexsmart reported suspending sales and described a phase-out of the current Guardian models.&nbsp;</span><span>If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.</span></i>"}],"value":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance."}],"source":{"discovery":"UNKNOWN"},"title":"Alert suppression through deauthentication-induced notification failure","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","assignerShortName":"ENISA","cveId":"CVE-2026-82950","datePublished":"2026-11-19T10:33:17.907Z","dateReserved":"2026-08-31T12:26:22.054Z","dateUpdated":"2026-11-19T16:54:54.934Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-19 11:17:08","lastModifiedDate":"2026-11-24 17:50:43","problem_types":["CWE-390","CWE-390 CWE-390: Detection of Error Condition Without Action"],"metrics":{"cvssMetricV40":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-19T16:52:42.933494Z","id":"CVE-2026-82950","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"82950","Ordinal":"1","Title":"Alert suppression through deauthentication-induced notification ","CVE":"CVE-2026-82950","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"82950","Ordinal":"1","NoteData":"The device only supports Wi-Fi protocols vulnerable to\ndeauthentication attacks (WEP/WPA/WPA2). Should any event which would typically\nbe logged to the user’s mobile device (such as arming or disarming the alarm or\nany tamper events) be incurred whilst the device is temporarily disconnected\nfrom its Wi-Fi network (such as via a deauthentication attack), those alerts\nwill not be sent even after connection is regained.","Type":"Description","Title":"Alert suppression through deauthentication-induced notification "}]}}}