{"api_version":"1","generated_at":"2026-10-09T07:47:30+00:00","cve":"CVE-2026-87674","urls":{"html":"https://cve.report/CVE-2026-87674","api":"https://cve.report/api/cve/CVE-2026-87674.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-87674","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-87674"},"summary":{"title":"CVE-2026-87674","description":"A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.","state":"PUBLISHED","assigner":"brocade","published_at":"2026-10-08 04:17:53","updated_at":"2026-10-09 04:18:13"},"problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":[{"version":"4.0","source":"sirt@brocade.com","type":"Secondary","score":"8.5","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.5","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://support.broadcom.com/external/content/SecurityAdvisories/0/39145","name":"https://support.broadcom.com/external/content/SecurityAdvisories/0/39145","refsource":"sirt@brocade.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-87674","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-87674","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Brocade","product":"Fabric OS","version":"affected 9.2.2d Brocade FabricOS","platforms":[]},{"source":"CNA","vendor":"Brocade","product":"Fabric OS","version":"affected 10.0.0 10.0.0a1 Brocade FabricOS","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"87674","cve":"CVE-2026-87674","epss":"0.001080000","percentile":"0.011140000","score_date":"2026-10-08","updated_at":"2026-10-09 00:01:23"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-87674","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-10-08T00:00:00+00:00","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-10-09T03:55:38.551Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Fabric OS","vendor":"Brocade","versions":[{"lessThan":"9.2.2d","status":"affected","version":"0","versionType":"Brocade FabricOS"},{"lessThanOrEqual":"10.0.0a1","status":"affected","version":"10.0.0","versionType":"Brocade FabricOS"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.</p>"}],"value":"A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation."}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-08T03:31:26.439Z","orgId":"87b297d7-335e-4844-9551-11b97995a791","shortName":"brocade"},"references":[{"url":"https://support.broadcom.com/external/content/SecurityAdvisories/0/39145"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<div>Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1</div>"}],"value":"Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"87b297d7-335e-4844-9551-11b97995a791","assignerShortName":"brocade","cveId":"CVE-2026-87674","datePublished":"2026-10-08T03:31:26.439Z","dateReserved":"2026-09-08T22:51:12.166Z","dateUpdated":"2026-10-09T03:55:38.551Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-08 04:17:53","lastModifiedDate":"2026-10-09 04:18:13","problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":{"cvssMetricV40":[{"source":"sirt@brocade.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-10-08T00:00:00+00:00","id":"CVE-2026-87674","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"87674","Ordinal":"1","Title":"CVE-2026-87674","CVE":"CVE-2026-87674","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"87674","Ordinal":"1","NoteData":"A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.","Type":"Description","Title":"CVE-2026-87674"}]}}}