{"api_version":"1","generated_at":"2026-10-21T11:24:09+00:00","cve":"CVE-2026-89201","urls":{"html":"https://cve.report/CVE-2026-89201","api":"https://cve.report/api/cve/CVE-2026-89201.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-89201","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-89201"},"summary":{"title":"CVE-2026-89201","description":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-10-13 10:17:21","updated_at":"2026-10-15 20:38:04"},"problem_types":["CWE-89","CWE-89 CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"7.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"7.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"baseScore":7.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-508506.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-508506.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-89201","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-89201","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM CROSSBOW","version":"affected V6.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"89201","cve":"CVE-2026-89201","epss":"0.003860000","percentile":"0.310550000","score_date":"2026-10-15","updated_at":"2026-10-16 00:06:12"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-89201","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-10-14T19:27:53.203857Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-10-14T19:28:00.768Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM CROSSBOW","vendor":"Siemens","versions":[{"lessThan":"V6.0","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."}],"metrics":[{"cvssV3_1":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},{"cvssV4_0":{"baseScore":7.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","description":"CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-13T09:19:05.287Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-508506.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2026-89201","datePublished":"2026-10-13T09:19:05.287Z","dateReserved":"2026-09-11T07:45:20.919Z","dateUpdated":"2026-10-14T19:28:00.768Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-13 10:17:21","lastModifiedDate":"2026-10-15 20:38:04","problem_types":["CWE-89","CWE-89 CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-10-14T19:27:53.203857Z","id":"CVE-2026-89201","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"89201","Ordinal":"1","Title":"CVE-2026-89201","CVE":"CVE-2026-89201","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"89201","Ordinal":"1","NoteData":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.","Type":"Description","Title":"CVE-2026-89201"}]}}}