Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
BID:107201
CVE-2019-6528 |Info
Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
| Bugtraq ID: | 107201 |
| Class: | Input Validation Error |
| CVE: |
CVE-2019-6528 |
| Remote: | Yes |
| Local: | No |
| Published: | Feb 28 2019 12:00AM |
| Updated: | Feb 28 2019 12:00AM |
| Credit: | M. Can Kurnaz |
| Vulnerable: |
PSI GridConnect GmbH Telecontrol Gateway XS-MU 5.1.19 PSI GridConnect GmbH Telecontrol Gateway XS-MU 5.0.27 PSI GridConnect GmbH Telecontrol Gateway XS-MU 4.2.21 PSI GridConnect GmbH Telecontrol Gateway VM 6.0.16 PSI GridConnect GmbH Telecontrol Gateway VM 5.1.19 PSI GridConnect GmbH Telecontrol Gateway VM 5.0.27 PSI GridConnect GmbH Telecontrol Gateway VM 4.2.21 PSI GridConnect GmbH Telecontrol Gateway 3G 6.0.16 PSI GridConnect GmbH Telecontrol Gateway 3G 5.1.19 PSI GridConnect GmbH Telecontrol Gateway 3G 5.0.27 PSI GridConnect GmbH Telecontrol Gateway 3G 4.2.21 PSI GridConnect GmbH Telecontrol Gateway 3G 0 PSI GridConnect GmbH Smart Telecontrol Unit TCG 6.0.16 PSI GridConnect GmbH Smart Telecontrol Unit TCG 5.1.19 PSI GridConnect GmbH Smart Telecontrol Unit TCG 5.0.27 PSI GridConnect GmbH IEC104 Security Proxy 2.2.10 |
| Not Vulnerable: |
PSI GridConnect GmbH Telecontrol Gateway XS-MU 6.0.17 PSI GridConnect GmbH Telecontrol Gateway XS-MU 5.1.20 PSI GridConnect GmbH Telecontrol Gateway VM 6.0.17 PSI GridConnect GmbH Telecontrol Gateway VM 5.1.20 PSI GridConnect GmbH Telecontrol Gateway 3G 6.0.17 PSI GridConnect GmbH Telecontrol Gateway 3G 5.1.20 PSI GridConnect GmbH Smart Telecontrol Unit TCG 6.0.17 PSI GridConnect GmbH Smart Telecontrol Unit TCG 5.1.20 PSI GridConnect GmbH IEC104 Security Proxy 2.2.11 |
Discussion
Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
Multiple PSI GridConnect GmbH Products are prone to a cross-site scripting vulnerability because it fails to sanitize user-supplied input.
An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks.
The following products are affected:
Telecontrol Gateway 3G 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Telecontrol Gateway XS-MU 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Telecontrol Gateway VM 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Smart Telecontrol Unit TCG 5.0.27, 5.1.19, 6.0.16 and prior
IEC104 Security Proxy 2.2.10 and prior
Multiple PSI GridConnect GmbH Products are prone to a cross-site scripting vulnerability because it fails to sanitize user-supplied input.
An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks.
The following products are affected:
Telecontrol Gateway 3G 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Telecontrol Gateway XS-MU 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Telecontrol Gateway VM 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior
Smart Telecontrol Unit TCG 5.0.27, 5.1.19, 6.0.16 and prior
IEC104 Security Proxy 2.2.10 and prior
Exploit / POC
Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
An attacker can exploit this issue by enticing an unsuspecting user into visiting a specially crafted URL.
An attacker can exploit this issue by enticing an unsuspecting user into visiting a specially crafted URL.
Solution / Fix
Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
Solution:
Updates are available. Please see the references or vendor advisory for more information.
Solution:
Updates are available. Please see the references or vendor advisory for more information.
References
Multiple PSI GridConnect GmbH Products CVE-2019-6528 Cross Site Scripting Vulnerability
References:
References:
- PSI GridConnect GmbH Homepage (PSI GridConnect GmbH)
- ICSA-19-059-01 PSI GridConnect Telecontrol (CERT)