Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
BID:108120
Info
Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
| Bugtraq ID: | 108120 |
| Class: | Input Validation Error |
| CVE: |
CVE-2019-6562 |
| Remote: | Yes |
| Local: | No |
| Published: | Apr 30 2019 12:00AM |
| Updated: | Apr 30 2019 12:00AM |
| Credit: | Rafael Honorato |
| Vulnerable: |
Philips Tasy EMR 3.2.1744 |
| Not Vulnerable: | |
Discussion
Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
Philips Tasy EMR is prone to a cross-site scripting vulnerability because it fails to properly sanitize user-supplied input.
An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and to launch other attacks.
Philips Tasy EMR version 3.02.1744 and prior are vulnerable.
Philips Tasy EMR is prone to a cross-site scripting vulnerability because it fails to properly sanitize user-supplied input.
An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and to launch other attacks.
Philips Tasy EMR version 3.02.1744 and prior are vulnerable.
Exploit / POC
Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
Currently, we are not aware of any working exploits. If you feel we are in error or if you are aware of more recent information, please mail us at: [email protected].
Currently, we are not aware of any working exploits. If you feel we are in error or if you are aware of more recent information, please mail us at: [email protected].
Solution / Fix
Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
Solution:
Currently, we are not aware of any vendor-supplied patches. If you feel we are in error or if you are aware of more recent information, please mail us at: [email protected].
Solution:
Currently, we are not aware of any vendor-supplied patches. If you feel we are in error or if you are aware of more recent information, please mail us at: [email protected].
References
Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability
References:
References:
- Philips Homepage (Philips)
- ICSMA-19-120-01: Philips Tasy EMR (ICS CERT)