Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
BID:50869
Info
Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
| Bugtraq ID: | 50869 |
| Class: | Input Validation Error |
| CVE: |
CVE-2011-2461 |
| Remote: | Yes |
| Local: | No |
| Published: | Nov 30 2011 12:00AM |
| Updated: | May 01 2012 05:21PM |
| Credit: | Adobe |
| Vulnerable: |
HP Systems Insight Manager 6.3 HP Systems Insight Manager 6.2 HP Systems Insight Manager 6.1 HP Systems Insight Manager 6.0.0.96 HP Systems Insight Manager 6.0 HP Systems Insight Manager 5.3 Update 1 HP Systems Insight Manager 5.3 HP Systems Insight Manager 5.2 SP2 HP Systems Insight Manager 5.1 SP1 HP Systems Insight Manager 5.0 SP6 HP Systems Insight Manager 5.0 SP5 HP Systems Insight Manager 5.0 SP3 HP Systems Insight Manager 5.0 SP2 HP Systems Insight Manager 5.0 SP1 HP Systems Insight Manager 5.0 HP Systems Insight Manager 4.2 SP2 HP Systems Insight Manager 4.2 SP1 HP Systems Insight Manager 4.2 Adobe Flex SDK 3.0.2 Adobe Flex SDK 3.0.1 Adobe Flex SDK 4.5.1 Adobe Flex SDK 4.5 Adobe Flex SDK 4.1 Adobe Flex SDK 4.0 Adobe Flex SDK 3.6 Adobe Flex SDK 3.5 Adobe Flex SDK 3.4 Adobe Flex SDK 3.3 Adobe Flash Builder 4.5 |
| Not Vulnerable: |
HP Systems Insight Manager 7.0 Adobe Flash Builder 4.6 |
Discussion
Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
Adobe Flex SDK is prone to a cross-site scripting vulnerability because it fails to properly sanitize user-supplied input to express-install template files.
An attacker could exploit this vulnerability to execute arbitrary script code in the context of a web application built using the SDK. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks.
Adobe Flex SDK 4.5.1 and prior versions are affected.
Adobe Flex SDK is prone to a cross-site scripting vulnerability because it fails to properly sanitize user-supplied input to express-install template files.
An attacker could exploit this vulnerability to execute arbitrary script code in the context of a web application built using the SDK. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks.
Adobe Flex SDK 4.5.1 and prior versions are affected.
Exploit / POC
Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
To exploit this issue, an attacker must entice a victim into following a malicious URI.
To exploit this issue, an attacker must entice a victim into following a malicious URI.
Solution / Fix
Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
Solution:
Updates are available. Please see the references for details.
Solution:
Updates are available. Please see the references for details.
References
Adobe Flex SDK CVE-2011-2461 Cross Site Scripting Vulnerability
References:
References:
- Flex SDK Homepage (Adobe)
- APSB11-25: Security update available for Flex SDK (Adobe)