QID 590578
Date Published: 2021-12-23
QID 590578: Emerson HART DTM Vulnerability (Update A) Denial of Service (DoS) Vulnerability (ICSA-15-008-01A)
AFFECTED PRODUCTS
The following products use the vulnerable HART DTM library and are affected:
Fisher Controls DVC6000 Digital Valve Controller Rev. 2.01,
Fisher Controls International DVC2000 Digital Valve Controller Rev. 1.01,
Micro Motion 1500 Rev. 5 and 6,
Micro Motion 1700 Analog Rev. 5 and 6,
Micro Motion 1700 IS Rev. 6,
Micro Motion 1700 Rev. 5,
Micro Motion 1700IS Rev. 5,
Micro Motion 2000 Config I/O Rev. 5,
Micro Motion 2200S Rev. 1,
Micro Motion 2400S Analog Rev. 2, 3, and 4,
Micro Motion 2500/2700 Config I/O Rev. 5 and 6,
Micro Motion 2700 Analog Rev. 5 and 6,
Micro Motion 2700 IS Rev. 5 and 6,
Micro Motion RFT9739 Rev. 4,
Micro Motion Series 3000 Rev. 7,
Rosemount 1151 Pressure Transmitter Rev. 5 and 6,
Rosemount 2051 Pressure Transmitter Rev. 3, 9, and 10,
Rosemount 2088 Pressure Transmitter Rev. 3, 9, and 10,
Rosemount 2090 Pressure Transmitter Rev. 3,
Rosemount 248 Temperature Transmitter Rev. 2,
Rosemount 3051 Pressure Transmitter Rev. 3, 7, 9, and 10,
Rosemount 3051S Advanced Diagnostics Rev. 2 and 3,
Rosemount 3051S Electronic Remote Sensors Rev. 1,
Rosemount 3051S Pressure Transmitter Rev. 7,
Rosemount 3051SMV Direct Process Variable Rev. 1,
Rosemount 3051SMV MultiVariable Mass Energy Flow Rev. 1,
Rosemount 3095M MultiVariable Mass Flow Rev. 2,
Rosemount 3100 Ultrasonic Level Transmitter Rev. 5,
Rosemount 3144P Temperature Transmitter Rev. 3, 4, 5, and 6
Rosemount 3300 Radar Level and Interface Transmitter Rev. 3,
Rosemount 333 Triloop Rev. 1,
Rosemount 4500 Pressure Transmitter Rev. 7,
Rosemount 4600 Pressure Transmitter Rev. 1,
Rosemount 5300 Radar Level and Interface Transmitter Rev. 1, 2, and 3,
Rosemount 5400 Radar Level Transmitter Rev. 1 and 2,
Rosemount 644 Temperature Transmitter Rev. 6, 7, 8, and 9,
Rosemount 8712D Magnetic Flowmeter Rev. 1,
Rosemount 8712E Magnetic Flowmeter Rev. 3,
Rosemount 8712H Magnetic Flowmeter Rev. 1,
Rosemount 8732C Magnetic Flowmeter Rev. 7,
Rosemount 8732E Magnetic Flowmeter Rev. 2,
Rosemount 8800C Vortex Flowmeter Rev. 3,
Rosemount 8800D Vortex Flowmeter Rev. 1 and 2,
Rosemount Analytical 1056 Rev. 1 and 2,
Rosemount Analytical 5081A Rev. 2,
Rosemount Analytical 5081CT Rev. 1,
Rosemount Analytical 5081p Rev. 2,
Rosemount Analytical 54eA Rev. 2,
Rosemount Analytical 54eC Rev. 1,
Rosemount Analytical 54epH Rev. 2,
Rosemount Analytical OCT4000 Rev. 3,
Rosemount Analytical OCX8800 Rev. 3,
Rosemount Analytical XmtA Rev. 1,
Rosemount Analytical XmtCT Rev. 1,
Rosemount Analytical XmtpH Rev. 1,
Rosemount Metran 150 Pressure Transmitter Rev. 9 and 10, and
Rosemount Metran 75 Pressure Transmitter Rev. 9 and 10.
QID Detection Logic (Authenticated):
QID checks for the Vulnerable version of using passive scanning
The vulnerability causes the HART DTM component to crash and also causes the HART service to stop responding. No loss of information or loss of control or view by the control system results from an attacker successfully exploiting this vulnerability.
Customers are advised to refer to CERT MITIGATIONS section ICSA-15-008-01A for affected packages and patching details.
- ICSA-15-008-01A -
www.us-cert.gov/ics/advisories/ICSA-15-008-01A
CVEs related to QID 590578
| Advisory ID | Software | Component | Link |
|---|---|---|---|
| ICSA-15-008-01A |
|