Affected Products
Stratix 5800 16.12.01 and earlier Stratix 8000 15.2(7)E3 and earlier Stratix 5700 15.2(7)E3 and earlier Stratix 5410 15.2(7)E3 and earlier Stratix 5400 15.2(7)E3 and earlier Stratix 8300 All Versions Stratix 5800 16.12.01 and earlier Stratix 5800 17.04.01 and earlier, if DECnet is enabled. Stratix 5800 16.12.01 and earlier Stratix 5800 16.12.01 and earlier Stratix 5800 17.04.01 and earlier Stratix 5800 17.04.01 and earlier

QID Detection Logic (Authenticated):
QID checks for the Vulnerable version of using passive scanning

A vulnerability in the CLI command permissions of Cisco IOS and Cisco IOS XE software could allow an authenticated, local attacker to retrieve the password for Common Industrial Protocol (CIP) and then remotely configure the affected device as an administrative user.

  • CVSS V3 rated as High - 7.8 severity.
  • CVSS V2 rated as Critical - 8.5 severity.
  • Solution

    Customers are advised to refer to CERT MITIGATIONS section PN1558 for affected packages and patching details.

    Software Advisories
    Advisory ID Software Component Link
    PN1558 URL Logo rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1130763