QID 591217

Date Published:

QID 591217: Schneider Electric EcoStruxure Panel Server Box Multiple Vulnerabilties (SEVD-2022-284-02)

The EcoStruxure Panel Server Box (PAS900) product is a cloud connected gateway with 4G/WIFI/Ethernet that supports Modbus TCP/RTU for south communication.

CVE-2022-30790 - Out-of-Bounds Write vulnerability exists that could cause arbitrary writes when crafted malformed packets are received from a local network while U-boot is running.
CVE-2022-30552 - Buffer Copy without Checking Size of Input vulnerability exists that could cause Denial of Service when a specially crafted fragmented IP Datagram with an invalid total length is received from a local network while U-boot is running.

Affected Versions
EcoStruxure Panel Server Box (PAS900) V3.1.16 and prior

QID Detection Logic (Authenticated)
QID checks for the Vulnerable version using passive scanning

Successful exploitation of these vulnerabilities could allow arbitrary code execution and disclose information.

  • CVSS V3 rated as High - 7.8 severity.
  • CVSS V2 rated as High - 7.2 severity.
  • Solution

    Customers are advised to refer to CERT MITIGATIONS section SEVD-2022-284-02 for affected packages and patching details.

    CVEs related to QID 591217

    Software Advisories
    Advisory ID Software Component Link
    SEVD-2022-284-02 URL Logo download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-284-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-284-02-EcoStruxure_Panel_Server_Box_PAS900_Security_Notification.pdf&_ga=2.83643921.624978513.1669086152-875239440.1662434919