Known Vulnerabilities for Sigma Spectrum Infusion System by Baxter

Listed below are 10 of the newest known vulnerabilities associated with "Sigma Spectrum Infusion System" by "Baxter".

These CVEs are retrieved based on exact matches on listed software, hardware, and vendor information (CPE data) as well as a keyword search to ensure the newest vulnerabilities with no officially listed software information are still displayed.

Data on known vulnerable versions is also displayed based on information from known CPEs

Known Vulnerabilities

CVE Shortened Description Severity Publish Date Last Modified
CVE-2020-12047 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in... 9.8 - CRITICAL 2020-06-29 2020-07-08
CVE-2020-12045 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model... 9.8 - CRITICAL 2020-06-29 2020-07-08
CVE-2020-12043 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service ope... 9.8 - CRITICAL 2020-06-29 2020-07-08
CVE-2020-12041 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive d... 9.4 - CRITICAL 2020-06-29 2020-07-08
CVE-2020-12040 Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) a... 9.8 - CRITICAL 2020-06-29 2020-07-09
CVE-2020-12039 Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v... 2.4 - LOW 2020-06-29 2020-07-09
CVE-2014-5434 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a defau... 9.8 - CRITICAL 2019-03-26 2019-10-09
CVE-2014-5433 An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cl... 9.8 - CRITICAL 2019-03-26 2019-10-09
CVE-2014-5432 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely... 9.8 - CRITICAL 2019-03-26 2019-10-09
CVE-2014-5431 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a ... 6.8 - MEDIUM 2019-03-26 2019-10-09
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.