Known Vulnerabilities for Simatic S7-1200 Cpu 1214 Fc Firmware by Siemens
Listed below are 10 of the newest known vulnerabilities associated with "Simatic S7-1200 Cpu 1214 Fc Firmware" by "Siemens".
These CVEs are retrieved based on exact matches on listed software, hardware, and vendor information (CPE data) as well as a keyword search to ensure the newest vulnerabilities with no officially listed software information are still displayed.
Data on known vulnerable versions is also displayed based on information from known CPEs
Known Vulnerabilities
| CVE | Shortened Description | Severity | Publish Date | Last Modified |
|---|---|---|---|---|
| CVE-2022-30694 json | The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticat... | 6.5 - MEDIUM | 2022-11-08 | 2023-04-11 |
| CVE-2021-44695 json | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker ... | 4.9 - MEDIUM | 2022-12-13 | 2023-09-12 |
| CVE-2021-44694 json | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker ... | 5.5 - MEDIUM | 2022-12-13 | 2023-09-12 |
| CVE-2021-44693 json | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker ... | 4.9 - MEDIUM | 2022-12-13 | 2023-09-12 |
| CVE-2021-40365 json | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker ... | 7.5 - HIGH | 2022-12-13 | 2023-09-12 |
| CVE-2021-3449 json | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 r... | 5.9 - MEDIUM | 2021-03-25 | 2023-11-07 |
| CVE-2013-2780 json | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and cont... | 7.8 - HIGH | 2013-04-22 | 2022-02-01 |
| CVE-2013-0700 json | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and cont... | 7.8 - HIGH | 2013-04-22 | 2022-02-01 |
| CVE-2012-3040 json | Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote at... | 4.3 - MEDIUM | 2012-10-10 | 2022-02-01 |
| CVE-2012-3037 json | The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authori... | 4.3 - MEDIUM | 2012-09-25 | 2022-02-01 |