| CVE | Shortened Description | Severity | Publish Date | Last Modified |
|---|---|---|---|---|
| CVE-2016-2846 | Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism v... | 6.5 - MEDIUM | 2016-03-16 | 2016-12-03 |
| CVE-2014-2909 | CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote at... | 5.8 - MEDIUM | 2014-04-25 | 2020-02-10 |
| CVE-2014-2908 | Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allo... | 4.3 - MEDIUM | 2014-04-25 | 2018-05-25 |
| CVE-2014-2258 | Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-... | 7.8 - HIGH | 2014-03-24 | 2020-02-10 |
| CVE-2014-2256 | Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-... | 7.8 - HIGH | 2014-03-24 | 2020-02-10 |
| CVE-2014-2254 | Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-... | 7.8 - HIGH | 2014-03-24 | 2020-02-10 |
| CVE-2014-2252 | Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-... | 6.1 - MEDIUM | 2014-03-24 | 2020-02-10 |
| CVE-2014-2250 | The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entr... | 8.3 - HIGH | 2014-03-24 | 2020-02-10 |
Known Affected Configurations (CPE V2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Operating System | Siemens | Simatic S7 Cpu 1200 Firmware | 4.0 | All | All | All |
| Operating System | Siemens | Simatic S7 Cpu 1200 Firmware | 3.0.2 | All | All | All |
| Operating System | Siemens | Simatic S7 Cpu 1200 Firmware | 3.0 | All | All | All |
| Operating System | Siemens | Simatic S7 Cpu 1200 Firmware | 2.0 | All | All | All |