Known Vulnerabilities for Simatic Wincc Runtime Advanced by Siemens
Listed below are 10 of the newest known vulnerabilities associated with "Simatic Wincc Runtime Advanced" by "Siemens".
These CVEs are retrieved based on exact matches on listed software, hardware, and vendor information (CPE data) as well as a keyword search to ensure the newest vulnerabilities with no officially listed software information are still displayed.
Data on known vulnerable versions is also displayed based on information from known CPEs
Known Vulnerabilities
| CVE | Shortened Description | Severity | Publish Date | Last Modified |
|---|---|---|---|---|
| CVE-2021-27386 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2022-01-04 |
| CVE-2021-27385 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2022-10-25 |
| CVE-2021-27384 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 9.8 - CRITICAL | 2021-05-12 | 2021-12-16 |
| CVE-2021-27383 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2021-12-16 |
| CVE-2021-25662 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2021-12-16 |
| CVE-2021-25661 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2021-12-16 |
| CVE-2021-25660 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All version... | 7.5 - HIGH | 2021-05-12 | 2021-12-16 |
| CVE-2021-3449 | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 r... | 5.9 - MEDIUM | 2021-03-25 | 2023-11-07 |
| CVE-2020-7592 | A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATI... | 6.5 - MEDIUM | 2020-07-14 | 2020-07-22 |
| CVE-2020-7580 | A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All vers... | 6.7 - MEDIUM | 2020-06-10 | 2023-04-28 |
Known Affected Configurations (CPE V2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Siemens | Simatic Wincc Runtime Advanced | 15.1 | - | All | All |
| Application | Siemens | Simatic Wincc Runtime Advanced | 15.1 | update1 | All | All |
| Application | Siemens | Simatic Wincc Runtime Advanced | 15.1 | update2 | All | All |
| Application | Siemens | Simatic Wincc Runtime Advanced | 15.1 | update3 | All | All |