CVE-2016-8358
Summary
| CVE | CVE-2016-8358 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2017-02-13 22:59:00 UTC |
| Updated | 2025-04-20 01:37:25 UTC |
| Description | An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints. |
Risk And Classification
Primary CVSS: v3.0 8.5 HIGH from [email protected]
CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Problem Types: CWE-346 | Smiths-Medical CADD-Solis Medication Safety Software MITM
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Primary | 8.5 | HIGH | CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 6 | AV:N/AC:M/Au:S/C:P/I:P/A:P |
CVSS v3.0 Breakdown
Attack Vector
NetworkAttack Complexity
HighPrivileges Required
LowUser Interaction
NoneScope
ChangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
NetworkAccess Complexity
MediumAuthentication
SingleConfidentiality
PartialIntegrity
PartialAvailability
PartialAV:N/AC:M/Au:S/C:P/I:P/A:P
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Smiths-medical | Cadd-solis Medication Safety Software | 1.0 | All | All | All |
| Application | Smiths-medical | Cadd-solis Medication Safety Software | 2.0 | All | All | All |
| Application | Smiths-medical | Cadd-solis Medication Safety Software | 3.0 | All | All | All |
| Application | Smiths-medical | Cadd-solis Medication Safety Software | 3.1 | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Na | Smiths-Medical CADD-Solis Medication Safety Software Through 3.1 | affected Smiths-Medical CADD-Solis Medication Safety Software through 3.1 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Smiths-Medical CADD-Solis Medication Safety Software Vulnerabilities | ICS-CERT | af854a3a-2127-422b-91ae-364da2661108 | ics-cert.us-cert.gov | Third Party Advisory, US Government Resource |
| Smiths-Medical CADD-Solis Medication Safety Software Multiple Security Bypass Vulnerabilities | af854a3a-2127-422b-91ae-364da2661108 | www.securityfocus.com | Third Party Advisory, VDB Entry |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.