CVE-2017-6079
Summary
| CVE | CVE-2017-6079 |
|---|---|
| State | PUBLISHED |
| Assigner | mitre |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2017-05-16 17:29:00 UTC |
| Updated | 2025-04-20 01:37:25 UTC |
| Description | The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006. |
Risk And Classification
Primary CVSS: v3.1 9.8 CRITICAL from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Problem Types: NVD-CWE-noinfo | n/a
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 9.8 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 10 | AV:N/AC:L/Au:N/C:C/I:C/A:C |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
NetworkAccess Complexity
LowAuthentication
NoneConfidentiality
CompleteIntegrity
CompleteAvailability
CompleteAV:N/AC:L/Au:N/C:C/I:C/A:C
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Ribboncommunications | Edgemarc 4550 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4552 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4601 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4700 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4750 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4800 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4806 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 4808 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 7301 | - | All | All | All |
| Hardware | Ribboncommunications | Edgemarc 7400 | - | All | All | All |
| Operating System | Ribboncommunications | Edgemarc Firmware | - | All | All | All |
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| CVE-2017-6079 – Blind Command Injection in Edgewater Edgemarc Devices | af854a3a-2127-422b-91ae-364da2661108 | depthsecurity.com | Exploit, Technical Description, Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.