CVE-2017-7915
Summary
| CVE | CVE-2017-7915 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2017-05-29 16:29:00 UTC |
| Updated | 2025-04-20 01:37:25 UTC |
| Description | An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. |
Risk And Classification
Primary CVSS: v3.0 9.8 CRITICAL from [email protected]
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Problem Types: CWE-307 | CWE-307 CWE-307
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Primary | 9.8 | CRITICAL | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 7.5 | AV:N/AC:L/Au:N/C:P/I:P/A:P |
CVSS v3.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
NetworkAccess Complexity
LowAuthentication
NoneConfidentiality
PartialIntegrity
PartialAvailability
PartialAV:N/AC:L/Au:N/C:P/I:P/A:P
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Moxa | Oncell 5004-hspa | - | All | All | All |
| Operating System | Moxa | Oncell 5004-hspa Firmware | All | All | All | All |
| Hardware | Moxa | Oncell 5104-hsdpa | - | All | All | All |
| Operating System | Moxa | Oncell 5104-hsdpa Firmware | All | All | All | All |
| Hardware | Moxa | Oncell 5104-hspa | - | All | All | All |
| Operating System | Moxa | Oncell 5104-hspa Firmware | All | All | All | All |
| Hardware | Moxa | Oncell G3110-hsdpa | - | All | All | All |
| Operating System | Moxa | Oncell G3110-hsdpa Firmware | All | All | All | All |
| Hardware | Moxa | Oncell G3110-hspa | - | All | All | All |
| Operating System | Moxa | Oncell G3110-hspa Firmware | All | All | All | All |
| Hardware | Moxa | Oncell G3150-hsdpa | - | All | All | All |
| Operating System | Moxa | Oncell G3150-hsdpa Firmware | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Na | Moxa OnCell | affected Moxa OnCell | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Moxa OnCell | ICS-CERT | af854a3a-2127-422b-91ae-364da2661108 | ics-cert.us-cert.gov | US Government Resource |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.