CVE-2020-9075
Summary
| CVE | CVE-2020-9075 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2020-06-15 15:15:00 UTC |
| Updated | 2021-07-21 11:39:00 UTC |
| Description | Huawei products Secospace USG6300;USG6300E with versions of V500R001C30,V500R001C50,V500R001C60,V500R001C80,V500R005C00,V500R005C10;V600R006C00 have a vulnerability of insufficient input verification. An attacker with limited privilege can exploit this vulnerability to access a specific directory. Successful exploitation of this vulnerability may lead to information leakage. |
Risk And Classification
Problem Types: CWE-20
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Huawei | Secospace Usg6300 | - | All | All | All |
| Hardware | Huawei | Secospace Usg6300 | - | All | All | All |
| Operating System | Huawei | Secospace Usg6300 Firmware | v500r005c00 | All | All | All |
| Operating System | Huawei | Secospace Usg6300 Firmware | v500r005c10 | All | All | All |
| Operating System | Huawei | Secospace Usg6300 Firmware | v500r005c00 | All | All | All |
| Operating System | Huawei | Secospace Usg6300 Firmware | v500r005c10 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c30 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c50 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c60 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c80 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c30 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c50 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c60 | All | All | All |
| Operating System | Huawei | Secospace Usg6600 Firmware | v500r001c80 | All | All | All |
| Hardware | Huawei | Usg6300e | - | All | All | All |
| Hardware | Huawei | Usg6300e | - | All | All | All |
| Operating System | Huawei | Usg6300e Firmware | v600r006c00 | All | All | All |
| Operating System | Huawei | Usg6300e Firmware | v600r006c00 | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Security Advisory - Insufficient Input Verification of Some Huawei products | MISC | www.huawei.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.