CVE-2021-27410
Summary
| CVE | CVE-2021-27410 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2021-06-11 17:15:00 UTC |
| Updated | 2021-06-24 15:07:00 UTC |
| Description | The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). |
Risk And Classification
Problem Types: CWE-787
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Hillrom | Connex Central Station | All | All | All | All |
| Application | Hillrom | Connex Device Integration Suite Network Connectivity Engine | All | All | All | All |
| Application | Hillrom | Connex Integrated Wall System | All | All | All | All |
| Application | Hillrom | Connex Spot Monitor | All | All | All | All |
| Application | Hillrom | Connex Vital Signs Monitor | All | All | All | All |
| Application | Hillrom | Service Monitor | All | All | All | All |
| Application | Hillrom | Service Tool | All | All | All | All |
| Application | Hillrom | Software Development Kit | All | All | All | All |
| Application | Hillrom | Spot Vital Signs 4400 | All | All | All | All |
| Application | Hillrom | Spot Vital Signs 4400 | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Hillrom Medical Device Management | CISA | MISC | us-cert.cisa.gov | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.