CVE-2021-44000
Summary
| CVE | CVE-2021-44000 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2022-02-09 16:15:00 UTC |
| Updated | 2022-06-14 10:15:00 UTC |
| Description | A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053) |
Risk And Classification
Problem Types: CWE-787
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Siemens | Jt2go | All | All | All | All |
| Application | Siemens | Solid Edge | se2021 | - | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack1 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack2 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack3 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack4 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack5 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack6 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack7 | All | All |
| Application | Siemens | Solid Edge | se2021 | maintenance_pack8 | All | All |
| Application | Siemens | Solid Edge | se2022 | - | All | All |
| Application | Siemens | Teamcenter Visualization | All | All | All | All |
| Application | Siemens | Teamcenter Visualization | 12.4.0 | All | All | All |
| Application | Siemens | Teamcenter Visualization | 13.1.0 | All | All | All |
| Application | Siemens | Teamcenter Visualization | 13.2.0 | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf | MISC | cert-portal.siemens.com | |
| ZDI-22-335 | Zero Day Initiative | MISC | www.zerodayinitiative.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Legacy QID Mappings
- 590790 Siemens Solid Edge and JT2Go Multiple Vulnerabilities (ICSA-22-041-07)