Security Advisory 0199
Summary
| CVE | CVE-2026-114625 |
|---|---|
| State | PUBLISHED |
| Assigner | Arista |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-10-22 21:17:16 UTC |
| Updated | 2026-10-23 04:18:13 UTC |
| Description | VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator. On an affected system, any authenticated user can gain operator privileges and masquerade as a local "superuser operator" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible. Hosted, including Dedicated, versions of VCO were impacted and have already been patched. |
Risk And Classification
Primary CVSS: v4.0 9.4 CRITICAL from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-89 | CWE-89 CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 9.4 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/C... |
| 4.0 | CNA | CVSS | 9.4 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H |
| 3.1 | [email protected] | Secondary | 9.9 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |
| 3.1 | CNA | CVSS | 9.9 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |
CVSS v4.0 Breakdown
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Arista Networks | VeloCloud Orchestrator | affected 5.2.0 5.2.3.18 custom | VeloCloud Orchestrator On-Prem |
| CNA | Arista Networks | VeloCloud Orchestrator | affected 6.1.0 6.1.3.10 custom | VeloCloud Orchestrator On-Prem |
| CNA | Arista Networks | VeloCloud Orchestrator | affected 6.4.0 6.4.2.12 custom | VeloCloud Orchestrator On-Prem |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.arista.com/en/support/advisories-notices/security-advisory/24838-securit... | [email protected] | www.arista.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Additional Advisory Data
Solutions
CNA: The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience. These vulnerabilities have been fixed in the following releases: - VCO 5.2.3.18 and later in the 5.2 train - VCO 6.1.3.10 and later in the 6.1 train - VCO 6.4.2.12 and later in the 6.4 train
Workarounds
CNA: Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment: - Restrict access to the VCO web interface to trusted administrative networks. - Monitor the VCO for accesses from known malicious source IPs. - Monitor for unexpected outbound network activity from the VCO host. - Consider blocking outbound ports not needed for normal activities. - Monitor for backdoor daemons and webshells. - Review recent administrator activity for unexpected changes.