SPL Injection through Time Center Dashboard Drilldowns in Splunk Enterprise Security
Summary
| CVE | CVE-2026-131233 |
|---|---|
| State | PUBLISHED |
| Assigner | cisco |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-11-19 20:17:37 UTC |
| Updated | 2026-11-19 20:17:37 UTC |
| Description | In Splunk Enterprise Security versions below 8.7.0, a user that holds a role with the run_collect capability could store attacker-controlled values in endpoint summary data. If another user who can access the Time Center dashboard selects an affected row, Splunk Enterprise Security could run attacker-controlled Search Processing Language (SPL) commands using the permissions of the user who selects the row. The user who stores the values could then access sensitive data and modify some data available to the user who selects the row. The vulnerability is possible because the Time Center dashboard does not safely escape endpoint summary values before inserting them into drilldown searches. For more information see Define roles on the Splunk platform with capabilities (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/define-roles-on-the-splunk-platform-with-capabilities) and Endpoint dashboards (https://help.splunk.com/en/splunk-enterprise-security-8/user-guide/8.7/analytics/endpoint-dashboards) in the Splunk documentation. |
Risk And Classification
Primary CVSS: v3.1 5.4 MEDIUM from [email protected]
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N
Problem Types: CWE-116 | CWE-116 The software prepares a structured message for communication with another component, but encoding or escaping of the data is either missing or done incorrectly. As a result, the intended structure of the message is not preserved.
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 5.4 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N |
| 3.1 | CNA | CVSS | 5.4 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N |
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Splunk | Splunk Enterprise Security | affected 8.7.0 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| advisory.splunk.com/advisories/SVD-2026-1106 | [email protected] | advisory.splunk.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Additional Advisory Data
Solutions
CNA: Upgrade Splunk Enterprise Security and Splunk App for PCI Compliance to version 8.7.0 or higher.
Workarounds
CNA: The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround. See [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/configuration-file-reference/10.4.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web.