Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability
Summary
| CVE | CVE-2026-3558 |
|---|---|
| State | PUBLISHED |
| Assigner | zdi |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-03-16 14:19:48 UTC |
| Updated | 2026-04-27 14:48:21 UTC |
| Description | Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374. |
Risk And Classification
Primary CVSS: v3.0 8.1 HIGH from [email protected]
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
EPSS: 0.001140000 probability, percentile 0.297380000 (date 2026-04-27)
Problem Types: CWE-306 | CWE-306 CWE-306: Missing Authentication for Critical Function
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Secondary | 8.1 | HIGH | CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N |
| 3.0 | CNA | CVSS | 8.1 | HIGH | CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N |
CVSS v3.0 Breakdown
Attack Vector
AdjacentAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
NoneCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Philips | Hue Bridge V2 | - | All | All | All |
| Operating System | Philips | Hue Bridge V2 Firmware | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Philips | Hue Bridge | affected 1.73.1973146020 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.zerodayinitiative.com/advisories/ZDI-26-156 | [email protected] | www.zerodayinitiative.com | Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.