Occupancy monitoring via unencrypted RF communication

Summary

CVECVE-2026-82949
StatePUBLISHED
AssignerENISA
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-11-19 11:17:08 UTC
Updated2026-11-19 16:22:00 UTC
DescriptionThe static codes used for information transmission throughout the 433.92 MHz system of the Guardian 2 system allow an attacker in proximity to monitor the movements of users inside the premises where the sensors are set up. This is further aided by the fact that codes transmitted reveal sensor type, although sensor location cannot be inferred from this traffic alone.

Risk And Classification

Primary CVSS: v4.0 7.1 HIGH from a6d3dc9e-0591-4a13-bce7-0f5b31ff6158

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Problem Types: CWE-319 | CWE-319 CWE-319: Cleartext Transmission of Sensitive Information


VersionSourceTypeScoreSeverityVector
4.0a6d3dc9e-0591-4a13-bce7-0f5b31ff6158Secondary7.1HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS7.1HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS v4.0 Breakdown

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Confidentiality
High
Integrity
None
Availability
None
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Onyx Cookware ApS Nexsmart Guardian 2 Alarm System affected semver Not specified

References

ReferenceSourceLinkTags
medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardia... a6d3dc9e-0591-4a13-bce7-0f5b31ff6158 medium.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Elias Lindström (en)

CNA: CERT-SE (en)

Additional Advisory Data

Solutions

CNA: Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.