CVE-2020-16228
Summary
| CVE | CVE-2020-16228 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2020-09-11 13:15:00 UTC |
| Updated | 2023-12-12 21:15:00 UTC |
| Description | Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate. |
Risk And Classification
Problem Types: CWE-299
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Philips | Intellivue Mp2-mp90 | n | All | All | All |
| Hardware | Philips | Intellivue Mp2-mp90 | n | All | All | All |
| Operating System | Philips | Intellivue Mp2-mp90 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mp2-mp90 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx100 | - | All | All | All |
| Hardware | Philips | Intellivue Mx100 | - | All | All | All |
| Operating System | Philips | Intellivue Mx100 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx100 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx400 | - | All | All | All |
| Hardware | Philips | Intellivue Mx400 | - | All | All | All |
| Operating System | Philips | Intellivue Mx400 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx400 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx550 | - | All | All | All |
| Hardware | Philips | Intellivue Mx550 | - | All | All | All |
| Operating System | Philips | Intellivue Mx550 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx550 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx600 | - | All | All | All |
| Hardware | Philips | Intellivue Mx600 | - | All | All | All |
| Operating System | Philips | Intellivue Mx600 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx600 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx700 | - | All | All | All |
| Hardware | Philips | Intellivue Mx700 | - | All | All | All |
| Operating System | Philips | Intellivue Mx700 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx700 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx750 | - | All | All | All |
| Hardware | Philips | Intellivue Mx750 | - | All | All | All |
| Operating System | Philips | Intellivue Mx750 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx750 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx800 | - | All | All | All |
| Hardware | Philips | Intellivue Mx800 | - | All | All | All |
| Operating System | Philips | Intellivue Mx800 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx800 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue Mx850 | - | All | All | All |
| Hardware | Philips | Intellivue Mx850 | - | All | All | All |
| Operating System | Philips | Intellivue Mx850 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue Mx850 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue X2 | n | All | All | All |
| Hardware | Philips | Intellivue X2 | n | All | All | All |
| Operating System | Philips | Intellivue X2 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue X2 Firmware | - | All | All | All |
| Hardware | Philips | Intellivue X3 | n | All | All | All |
| Hardware | Philips | Intellivue X3 | n | All | All | All |
| Operating System | Philips | Intellivue X3 Firmware | - | All | All | All |
| Operating System | Philips | Intellivue X3 Firmware | - | All | All | All |
| Application | Philips | Patient Information Center Ix | b.02 | All | All | All |
| Application | Philips | Patient Information Center Ix | c.02 | All | All | All |
| Application | Philips | Patient Information Center Ix | c.03 | All | All | All |
| Application | Philips | Patient Information Center Ix | b.02 | All | All | All |
| Application | Philips | Patient Information Center Ix | c.02 | All | All | All |
| Application | Philips | Patient Information Center Ix | c.03 | All | All | All |
| Application | Philips | Performancebridge Focal Point | a.01 | All | All | All |
| Application | Philips | Performancebridge Focal Point | a.01 | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Philips Patient Monitoring Devices | CISA | MISC | us-cert.cisa.gov | Third Party Advisory, US Government Resource |
| Product Security | Philips | www.philips.com | ||
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.